SICK C2000 Manual Del Usuario página 266

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
Details about the points listed below must be present at least during initial commissioning — they are, however,
dependent on the respective application, the specifications of which are to be controlled by the manufacturer/installer.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1.
Have the safety rules and regulations been observed in compliance with the directives/standards applicable to
the machine?
2.
Are the applied directives and standards listed in the declaration of conformity?
3.
Does the protective device fulfil the required PL/SILCL and PFHd according to EN ISO 13 849-1/EN 62 061 and
the type according to EN 61 496-1?
4.
Is the access to the hazardous area/hazardous point only possible through the protective field of the ESPE?
5.
Have appropriate measures been taken to prevent (mechanical protection) or monitor unprotected presence in
the hazardous area when protecting a hazardous area/hazardous point and have these been secured against
removal?
6.
Are additional mechanical protective measures fitted and secured against manipulation which prevent reaching
under, over or around the ESPE?
7.
Has the maximum stopping and/or stopping/run-down time of the machine been measured, specified and
documented (at the machine and/or in the machine documentation)?
8.
Has the ESPE been mounted such that the required safety distance from the nearest hazardous point has been
achieved?
9.
Are the ESPE devices correctly mounted and secured against manipulation after adjustment?
10. Are the required protective measures against electric shock in effect (protection class)?
11. Is the control switch for resetting the protective device (ESPE) or restarting the machine present and correctly
installed?
12. Are the outputs of the ESPE (OSSDs, AS-Interface Safety at Work) integrated in compliance with the required
PL/SILCL according to EN ISO 13 849-1/EN 62 061 and does the integration comply with the circuit diagrams?
13. Has the protective function been checked in compliance with the test notes of this documentation?
14. Are the given protective functions effective at every setting of the operating mode selector switch?
15. Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?
16. Is the ESPE effective over the entire period of the dangerous state?
17. Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when changing the
operating mode, or when switching to another protective device?
18. Has an information label for the daily check been attached so that it is easily visible for the operator?
This checklist does not replace the initial commissioning, nor the regular inspection by qualified safety personnel.
iv
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Update
Checklist for the manufacturer
Checklist for the manufacturer/installer for the installation of electro-
sensitive protective equipment (ESPE)
Insert
C2000/M2000
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
8008684/YJC8/2015-03-30