Electrical data
C 2000
Test input
NC contact, U
Pulse duration > 20 ms +
max. response time
RES
U
U
EDM
SEL 1, SEL 2
"1" = open, "0" < 0.8 V
HRANGE
Operating data
C 2000
Protection class
III *)
Enclosure rating
IP 65
Safety category
2
Ambient operating
0° C ... +55° C
temperature
Storage temperature
–25° C ... +70° C
Air humidity
15 ... 95 %
Rigidity
5 g/10 Hz ... 55 Hz to IEC 68-2-6
Shock resistance
10 g/16 ms to IEC 68-2-29
Weight
Dependent on type, between
0.27 kg and 3.88 kg
Table 9-1: Data sheet C 2000, M 2000 and M 2000-A/P (continued from previous page)
*) The circuits connected to the input and output must maintain the creepage and clearance distances
stipulated for safe isolation in the relevant standards.
8008684/YJC8/2015-03-30
8 008 684/RI57/2007-11-28
Technical Data
= U
, "1" > 14 V, "0" < 9 V, I
max
B
= U
, "1" > 8 V, "0" < 4 V
max
B
= U
, "1" > 14 V, "0" < 9 V
max
B
Fig. 9-1: Inductive switching power of the OSSD outputs as a function of
switching rate and load current
a = Load inductance (Henry)
s = Switching rate (1/s)
© SICK AG • Safety Systems • Germany • All rights reserved
M 2000
= 1.2 mA bat24 V
Test
Pulse duration > 15 ms +
max. response time
"1" > 14 V, "0" < 9 V, I
HRange
M 2000
Dependent on type, between
1.25 kg and 2.86 kg
d = Load current 400 mA
f = Load current 500 mA
Chapter 9
M 2000-A/P
Pulse duration > 15 ms +
max. response time
= 1 mA at 24 V
M 2000-A/P
1.41 kg
2 7 9