has a grounded type plug that includes a third
(grounding)
pin. This plug witl on!y fit a grounded type
outlet.
If you do not have a grounded outlet, contact
a qualified licensed electrician to install onel DO NOT
alter the plug in any way. The d_r opener must be
properly grounded in order to prevent personal injury
and
damage to the components.
•
DO NOT remove motor coVerl All Work performed
on motor must be done by a trained door system
technician.
are not required to have your garage door opener
permanently
wired, with circuit breaker protection:
If bui!ding codes require door opener to be
Permanently wired have aqua ified licensed
electrician connect power with permanent wiring.
Plug the opener into a properly grounded
electrical
outlet (Fig. 5-1).
Instructions
for Electrician.
• Remove power from circuit.
• Remove rear cover and motor cover.
- Remove four motor cover screws (Fig. 5-2).
• Remove existing power cord and strain relief
from the 7/8" dia. hole and discard (Fig. 5-3).
• Connect
permanent wiring to power head using
7/8" diameter hole.
-White
to white/black to black/ground
to green.
-Use
only UL recognized
wire nuts.
• Wires inside the power head must be at least 6"
in length.
• Replace motor cover and rear cover and
re-energize
the circuit.
HOTLY!? 'T_ (S_enk,? C o_9_ny
Ls re
<espon_J_b?,<,_
FOr
@_s,r;gs resuF_J<:_9 _ o;¢ w®_g,_ p mfbm, ed @ _n
Check Safe-T-Beam
®alignment
(Fig. 5-4).
• Insure that no part of door or its hardware
is
in path between lenses of source
and sensor.
• Insure that tops of lenses are between 5" - 6"
above the floor (Fig. 5-4). The brackets are
flexible, and can be adjusted slightly if needed.
• Adjust the Red LED transmitter
by aiming the
unit directly at the Green LED receiver. Use the
adjustment
screw located on the top of the
transmitter
housing to make adjustments.
• The Red LED transmitter
will blink if there is a
misalignment.
When the LED units are aligned
the Red LED will remain ON continuously.
• After the alignment
is finished tighten the
adjustment
screws on both sensors.
FIG. 5-1
Connect to power.
Motor Cover Screws
FIG. 5-2
Remove motor cover.
FIG. 5-3
Power cord strain relief.
Do NOT use an extension
cord.
Do NOT use a portable generator. This product
is designed to operate using standard
household
current.
Do NOT use alternate
power supplies.
FIG. 5,4 Check
Safe,T-Beam® alignment.
,
,
3.
,
When the garage door is opening, its movement
will not be influenced
if the Safe-T-Beam ® is
obstructed.
If the Safe-T-Beam ®is obstructed
before
the
garage door fully closes, the door will not close.
When the garage door is closing, if Safe-T-Beam ®
is cut off by people or obstacle, the garage door
will reverse automatically to its fully opened position.
(Meanwhile, the opener light will keep blinking until
door moves to its fully opened position.)
If the Safe-T-Beam ®System fails, loses power,
or is installed improperly, you will have to press
and hold the Wall Button "close" button until the
door reaches its fully closed position. The LED
indicator light on the power head will be green
and blink twice (Pattern: C-_ pause _
pause)
to inform you to eliminate problem first.
Otherwise,
the door will reverse automatically
to
its fully opened position if you release the
"close" button on the Wall Button during the
closing movement.
I
PN# 36420Supplement,
10/27/2008
19