12. INSTALL THE ROUGH-IN PLATE FOR EXTERNAL BLOWER
Refer to the instructions included with the selected blower/rough-in kit
(sold separately) for details on installing the rough-in plate. Install the
rough-in plate so that the wiring box is located on the right side when
facing the hood, as specified on the blower housing label.
13. CONNECT WIRING (ALL BLOWERS)
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power from being switched on accidentally.
Position the power pack below the installed custom hood.
INTERNAL BLOWERS: Insert the house wiring cable through the wire
clamp previously installed in step 8. Tighten the
wire clamp to secure the cable. Connect cable into
wiring box using wire connectors. Connect BLACK
to BLACK, WHITE to WHITE and GREEN or bare
wire under GREEN ground screw. DO NOT
FORGET TO CONNECT THE GROUND. Reinstall
wiring cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
14. REMOVE THE INTERNAL BLOWER(S)
In order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack
before installing the custom hood.