IND560 Installation Manual
sufficient so that no strain is placed on the connector assembly when the
housing is in the fully open position.
•
After making the wiring connections as described in the next section, ensure
the nut on the cable gland is tightened properly to seal around the cable.
Ensure that this seal is watertight.
•
Cable shielding should be grounded to the IND560's enclosure by spreading
the shield wires as shown at the top of Figure 2-14, then folding them back
over the plastic component of the cable gland before pressing it into the
threaded body.
Main Board Wiring Connections
Once the IND560 terminal harsh enclosure is open, connections can be made to
the terminal strips on the main board, as shown in Figure 2-15.
2-10
Figure 2-14: Cable Shield Grounding
Load Cell
COM1
SW2
Figure 2-15: Analog Main Board in Harsh Enclosure
AC power
Fuse
SW1