REMARKS:
In case of repeated ignition lock-outs, while pellets
are fed regularly, there may be a problem caused by a
failing electric glow plug. In this case, while you wait for a
technician, the pellet boiler stove can be manually started
by using solid fuel cubes (firelighters).
Manual starting procedure:
• open the door;
• take a solid fuel cube and place it inside the brazier
together with some pellets;
• light a match and set fire to the solid fuel inside the
brazier;
• wait a couple of minutes, close the door;
• follow the regular ignition procedure.
Do not use any flammable liquid to start
the stove. During the reload phase, do not
bring the bag of pellets in contact with
the hot thermostove.
Working power and water temperature settings
The heating power is set by the
and
. A heating
keys
power at Po 9 is suggested
during the first working hours of
the stove.
To set the water temperature press the key
You will see the words "SE T h2 o" blinking on the upper
display. You will read the water temperature on the lower
display.
Room temperature setting
To set the room temperature,
press the key
: twice: you
will see the words "SET AI R ",
blinking on the lower display.
You will read the set temperature
on the upper display.
Use the keys
e
to change the value.
Room temperature range: 7°C – 40 °C
Fan speed setting for hot air
It is possible to activate or deactivate the room ventilator
placed on the front part of the stove.
The fan can be set with 5 different working speeds.
To set the fan for hot air, please join the following procedure:
press the key
twice to enter the setting menu for room
temperature.
On the upper display, next to the room temperature, there
is a value which can go from 0 to 5. Pressing the key to
increase power
If you set the value "0", you will deactivate
On the following example, the
fan for hot air is switched off.
The speed is set on "0".
On the following example, the
fan for hot air is working at its
highest speed 5.
Procedure to turn off the
thermostove
Turn off the pellet boiler stove by
pressing button
of seconds until "OF F" is shown
on the upper display
Pellet feeding will stop immediately but the thermostove
. only once.
will continue working until the accumulated heat is
fully consumed, turning itself off automatically after a
maximum of 30 minutes.
REMARKS:
The thermostove is fitted with
an automatic device that allows
cleaning the brazier after a
given period of time: when this
time is detected, the stove fire
automatically
"PU L F IRE "; is shown on the display. After some minutes,
the thermostove will start working regularly.
operation of the fumes extraction fan is normal
and may indicate that the stove is still hot. In the
event of low temperatures, it might happen that
the stove starts the smokes fan and circulator for
some minutes in order to prevent ice formation
on the pipes of the system. in the event there is a
power drop, the main board will exhaust the smokes
residuals as soon as the power supply is back on.
In order to do that, the main board will increase
the speed and show the words "C O O L FIR E " on the
display. As soon as the cooling phase has been
completed, the stove will automatically start up
working as it was set before the power drop.
you can scroll the 5 available speeds.
This adjustment is only useful for turning
on and off the hot-air delivery system
because the temperature coming from
the grates depends on the thermostove
status.
, for a couple
reduces
and
Do not unplug the power plug to turn off
the thermostove; wait until the automatic
shutdown cycle finishes: the continuous
43