Descending- And Rescue-Device With Lifting Function; General; Before Using The Device - SKYLOTEC MILAN AGR 2001 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
Instrucion of use MILAN / MILAN 2.0
GB

Descending- and Rescue-Device with lifting Function

according to EN 341 Class A and EN 1496,ANSI/ASSE Z359.4-2013, CSA Z259.2.3

GENERAL:

The Milan rescue device is used for the rescue of persons from height, deep working areas and
confined spaces. The use is limited to persons
to use the device safely and have attended an appropriate user training course.
In order to rescue persons from a fall from height or suffering from other accidents as fast
as possible, there has to be an emergency rescue plan considering and preparing for all possible
emergency situations, which can be applied while using the device.
The rescue device is not a fall arrester!

1. BEFORE USING THE DEVICE

Prior to each application the user has to make sure the device is in good working order and the
full functionality of the device is assured. The device itself and the rope, including all other com-
ponents, are to be checked carefully.
It has to be ensured that:
the Milan rope has no damage at all and runs freely through the device in both directions
the end terminations are in good condition
all carabiners are free of damage
all screws are fixed
the device is free of damages like cracks or deformations
the anchor point is free of damages
the device is not polluted by chemicals, lubricants or others
the device is
there are no other anomalies
For
an
inspection anchor the device on a rigid structure and pull 1 meter rope out of the device.
The rope must slide out smoothly without abnormal mechanical sound.
This Inspection may be omitted only if the device is part of an emergency set which was
inspected by a competent person before and stored safely in a closed container.
If there is any doubt in regard on the condition of the device it has to be inspected by a competent
person and it is not allowed to be used until the inspection by a competent person has been com-
pleted. Devices which fail inspection have to be marked clearly to avoid
6
MAT-BA-0068-03_20200129_in_Bearbeitung.indd 6
MAT-BA-0068-03_20200129_in_Bearbeitung.indd 6
free from dirt or gross contaminants
who
are of good
health,
have been instructed
further
use.
29.01.2020 15:23:45
29.01.2020 15:23:45
Tabla de contenido
loading

Este manual también es adecuado para:

Milan hub agr 2001Milan 2.0Milan 2.0 hubMilan 2.0 power

Tabla de contenido