7.1 TESTING IN ACCORDANCE WITH EN 341 AND EN 1496 - PRINCIPLE
The standard stipulates the performance that is expected of the device before it can be ap-
proved. Once the requirements of the standard have been fulfilled, the device is approved and
classified. Nominally the device is then approved for work involving the abseiling definition. In the
case of the MILAN and MILAN 2.0 (class A) this means that the device is approved for an abseiling
distance of 10,000m with 1 person (75kg), for example 100 x 100 m or 20 x 500 m.
Where it is not an emergency situation, for instance during training, safety tolerances should
be maintained however, with regard to this maximum permissible load. The size of this safety
tolerances is not standardized. SKYLOTECs recommendations are as follows:
MAT-BA-0068-03_20200129_in_Bearbeitung.indd 19
MAT-BA-0068-03_20200129_in_Bearbeitung.indd 19
Yearly, according to the
Definition by site
instruction sticker on the
operator to define an
SEAL PAC box
appropriate person
na.
na.
MILAN service, cleaning
SKYLOTEC MILAN Ser-
inside, replacement
vice Level 3 training
of parts, resealing (acc.
to SKYLOTEC training, the
included instruction and
a detailed service documen-
tation)
• At least after 10 years,
the product is valid for
another 10 years. After
20 years max. the device
has to be discarded
• If the humidity indicator
on the SEAL PACS shows
a deviation
• After a rescue scenario
• documentation MUST be
done in HOMEBASE
Max. 20 years from
manufacturing date (month
+ year)
(if the replacement after
10
years has been done)
Inspection
Service LEVEL 2
na.
Service LEVEL 3
Replacement of the brake:
• At least after 10 years,
Product is valid for another
10 years (SEAL PAC Reseal
service only by SKYLOTEC
or SKYLOTEC
Competent service stations
MILAN Service Level 3 trained)
• Inspection / replacement
following the instructions on
the Level 3 service training
Replacement of textile com-
ponents (Ropes, harnesses,
slings): At least after 10 years
Max. lifespan