Pentair NOCCHI MULTI EVO Manual De Instrucciones página 22

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
ENGLISH
QUICk TROUBLE­
SHOOTINg gUIDE
Refer to the "safety instructions".
The pump does not work
•   No power supply = turn on the switch
and check that no electrical connec­
tions are loose or defective.
•   Check the mains voltage
•   Fuse blown = check that the cables
and relative connections are not de­
fective and replace the fuse if neces­
sary
•   The single phase motor thermal cu­
tout has tripped = this is reset auto­
matically once the motor has cooled
•   Motor overload cutout has tripped
= check that the cables and relative
connections are not defective, check
that the pump is not blocked mecha­
nically, or whether the pump winding
is damaged (replace if necessary)
•   Electrical power line damaged =
replace
•   Pump blocked mechanically = clean
The pump stops after a short interval of
operation due to a tripped motor pro-
tection device
•   Excessive current absorption = check
the operating condition of the pump
•   If foreign bodies are present, blocking
hydraulics = clean the hydraulic com­
ponents
•   Phase missing on power supply (three
phase motor) = check the electrical
power supply
•   The single phase motor thermal cu­
tout has tripped = this is reset auto­
22 22
matically once the motor has cooled;
check installation conditions
•   Thermal cutout protection setting or
fuses not suitable = check protection
devices with respect to rated current
of pump
•   Power cable damaged = replace
component
•   Motor damaged = replace component
The pump starts up but does not deliver
liquid
•   Pump is not primed = repeat the
"pump priming" procedure
•   The pump takes in air = check the
liquid level, operation of the foot valve
and the suction pipeline
•    The foot valve is blocked in the closed
position = replace or clean the valve
•   For self­priming pumps only: The li­
quid column above the check valve on
the delivery pipeline prevents self­pri­
ming of the pump = drain the delivery
pipeline. Check that check valve does
not retain liquid in the delivery pipe­
line. Repeat the start­up procedure.
Pump performance is reduced
•   Pipelines obstructed = check pipelines
•   Incorrect impeller rotation (three pha­
se motor) = check direction of rotation
•   Pump is not primed correctly = repeat
the "pump priming" procedure
•   For self­priming pumps only: the in­
ternal valve has not closed = gradually
close a valve until there is a visible in­
crease in pressure or flow. Then open
the valve gradually until the required
flow rate is reached.
Tabla de contenido
loading

Este manual también es adecuado para:

Nocchi multi evo a

Tabla de contenido