9
Technical data
9.1
Technical data - VWS
Description
Type
Area of application
Fuse
- Trigger characteristics
- Breaking current
Electrical power consumption
- Min. for B-5/W35
- Max. for B20/W60
- External auxiliary heater (on-site,
max.)
Coolant circuit
- Coolant type
Heat pump performance data
B0/W35 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W35 DT 10K In accordance with
DIN EN 255
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W55 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
Interior noise level
(B0/W35 in accordance with EN 12102)
Installation site
- Permitted ambient temperature
9.1 Technical data - VWS
Key
B0/W35 DT 5K:
B =
Brine
0 =
0 °C Inlet temperature/warm brine
W =
Heating water
35 = 35 °C Flow temperature
DT=
Temperature difference based on flow and return of the
heating mode
K =
Kelvin
Operating instructions geoTHERM 0020051578_03
Unit
VWS 220/2
–
The heat pumps are intended exclusively for domestic use as heating appliances
for closed heating and hot water systems and for hot water generation.
–
Operation of the pump outside the application limits results in the heat pump
being switched off by the internal control and safety installations.
C, three-pole switching (disconnection of the three mains connection lines by a
–
switching operation)
A
20
kW
5,0
kW
10,0
kW
3 x 2,3
-
The following performance data is applicable to new units with clean heat exchangers.
kW
22,0
kW
5,0
-
4,4
kW
22,3
kW
4,7
-
4,60
kW
20,3
kW
6,6
-
3,1
dB(A)
63
°C
Technical data
VWS 300/2
VWS 380/2
Brine-to-water heat pump
25
32
6,4
8,5
12,0
16,0
3 x 2,3
3 x 2,3
R 407 C
29,8
38,3
6,5
8,5
4,6
4,5
30,3
37,8
6,3
8,0
4,8
4,7
26,8
36,2
8,8
11,7
3,0
3,1
63
63
Interior/dry
7 - 25
9
VWS 460/2
40
10,1
18,0
3 x 2,3
45,9
10,0
4,6
45,5
9,7
4,7
42,3
14,1
3,0
65
49