9
Technical data
9.2
Technical data - VWW
Description
Type
Area of application
Fuse
- Trigger characteristics
- Breaking current
Electrical power consumption
- Min. for W10/W35
- Max. for W20/W60
- External auxiliary heater (on-site,
max.)
Coolant circuit
- Coolant type
Heat pump performance data
W10/W35 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
W10/W35 DT 10K In accordance with
DIN EN 255
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
W10/W55 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
Interior noise level
(W10/W35 in accordance with EN 12102)
Installation site
- Permitted ambient temperature
9.2 Technical data - VWW
Key
W10/W35 DT 5K:
W =
Water
10 = 10 °C Inlet temperature
W =
Heating water
35 = 35 °C Flow temperature
DT=
Temperature difference based on flow and return of the
heating mode
K =
Kelvin
50
Unit
VWW 220/2
–
The heat pumps are intended exclusively for domestic use as heating appliances
for closed heating and hot water systems and for hot water generation.
–
Operation of the pump outside the application limits results in the heat pump
being switched off by the internal control and safety installations.
C, three-pole switching (disconnection of the three mains connection lines by a
–
switching operation)
A
20
kW
4,9
kW
10,0
kW
3 x 2,3
-
The following performance data is applicable to new units with clean heat exchangers.
kW
29,9
kW
5,8
-
5,2
kW
30,2
kW
5,5
-
5,5
kW
26,9
kW
7,6
-
3,5
dB(A)
63
°C
VWW 300/2
VWW 380/2
Water-to-water heat pump
25
32
6,6
8,5
12,0
16,0
3 x 2,3
3 x 2,3
R 407 C
41,6
52,6
7,8
9,8
5,3
5,3
42,4
52,3
7,5
9,4
5,7
5,5
37,2
47,4
10,4
12,9
3,6
3,6
63
63
Interior/dry
7 - 25
Operating instructions geoTHERM 0020051578_03
VWW 460/2
40
10,2
18,0
3 x 2,3
63,6
12,4
5,1
64,7
12,0
5,4
57,3
15,8
3,6
65