salmson SIE Serie Instalacion Y Puesta En Servicio página 109

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

11.3.4 Error type E or F
1
2
3
4
9a
9b
Fig. 50: Error type E, diagram
1
2
3
4
5
Fig. 51: Error type F, diagram
6.0.0.0
E000
Fig. 52: Acknowledge error type E or F
Installation and operating instructions SIE-DIE-PBE
Error type E (Fig. 50):
5
6
7
8
Error type F (Fig. 51):
If type E or F errors occur, proceed as follows to acknowledge (Fig 52):
• To change to menu mode, press the red button.
Menu number <6.0.0.0> flashes on the display.
12.3
• Press the red button again.
The error is acknowledged, and the status page is displayed.
NOTE:
The error will be acknowledged automatically if the cause of the error
is eliminated.
Program
Contents
step/query
1
• Error code is displayed
• Pump goes into emergency operation
2
• Error meter is incremented
3
Error matrix AC or HV?
4
• SSM is activated
5
Error criterion fulfilled?
6
Error acknowledged?
7
Error matrix HV and > 30 minutes?
8
• SSM is activated
9a
End; auto control (double pump) resumes
9b
End; auto control (single pump) resumes
Yes
No
Program
Contents
step/query
1
• Error code is displayed
2
• Error meter is incremented
3
Error criterion fulfilled?
4
Error acknowledged?
5
End; auto control resumes
Yes
No
English
103
Tabla de contenido
loading

Este manual también es adecuado para:

Die seriePbe serie

Tabla de contenido