Use
3.1.3
Attaching the earmuffs (optional)
► Illustration on the fold-out page (Figure F)
1. Dismantle the adapters attached to the helmet:
To do this, push the adapter clips off the shell of the helmet and
remove the adapters.
2. Move the earmuffs into the folded position.
3. Insert the adapter into the guide and press the shell of the helmet
until the clips snap into place in the shell.
4. Adjust the earmuffs so that they cover the user's ears.
3.1.4
Don the Dräger X-plore 8000 helmet with visor.
WARNING
!
Danger through lack of oxygen and CO
Wait to close the visor until it is connected to the respiratory
protective device and breathable air is available.
1. Fold up the visor.
2. Put the helmet on.
3. Hold the face cuff by the tabs and pull it apart.
4. Pull the face cuff under the chin so that it tightly encloses the face.
18
3.2
!
poisoning!
2
3.3
Perform the following activities after use:
!
1. Take off the Dräger X-plore 8000 helmet with visor where the
ambient air is no longer contaminated.
2. Clean the Dräger X-plore 8000 helmet with visor (see section 4.1).

During use

WARNING
Risk of injury.
Danger through lack of oxygen, CO
penetration of contaminants from the ambient air!
Full user protection only is guaranteed
if the helmet fits in place optimally. The support ring must
be adjusted to the head circumference. Only wear the
helmet if it is completely assembled and ready for use
(see section 4.2.1).
if the visor is locked into the lowest position (usage
position).
if the face cuff fits tightly on the face.

After use

WARNING
Danger through lack of oxygen, CO
penetration of contaminants from the ambient air.
Do not switch off respiratory protective device while the
helmet is still closed.
Dräger X-plore 8000 Helmet with Visor
poisoning and
2
poisoning and
2