Programming is carried out in four steps, which are briefly
summarised here.
Start manual programming
1.
Disconnect the power supply — wait at least 20 s —
and reconnect the power supply.
1 : 1
When the electronics are booting, the LED in the
sensor field flashes red/yellow.
Do not put your hands into the sensor area during
this phase!
Afterwards the LED is red for max. 7 s. During this
red phase, cover the sensor field and keep it co-
vered. Programming mode is started.
Select function (F1 - F3)
2.
The functions are now indicated one at a time by the
flashing yellow LED (see table).
To select a function, uncover the sensor field when
the corresponding code is flashing.
20
Zustand der Armatur
5 mm
5 mm
Parameters:
Flush volume
Parameters:
Range
Stagnation flush
1 : 1
1 : 1
1 : 1
Wasser läuft
5 mm
Kein Wasser
Wasser läuft
Wenig Wasser
Kein Wasser
Wenig Wasser
Manual programming
Operating elements for programming:
1 LED (yellow / red)
2 Sensor field
The following table provides an overview of the main
programs and the available parameters for program-
ming the fitting manually:
P1
...
...
P = Dependiendo de la presión de flujo (véase la tabla de la pág. 16)
P1
Short
kurz
mittel
Off *
lang
In the pictures on pages 22 and 23, manual programming
is depicted step-by-step.
As an example it is shown how to set the "range" function
(F2) to "long" (P3).
Set parameters
3.
The flashing red LED shows you the currently set
1 : 1
parameter (see table).
By covering the sensor field again you can set the
corresponding parameter. The parameters are indica-
ted one at a time by the flashing red LED (see table).
To set a parameter, uncover the sensor area when
the corresponding code is flashing.
Start operation
4.
After leaving the sensor field, the programming
mode starts once again with a time window of 7
seconds (red LED is on continuously).
If the sensor field is not covered during these 7 se-
conds, the programming is completed. The fitting is
now ready for use.
Kein Wasser
Wenig Wasser
P15
P2
kurz
mittel
kurz
Medium *
lang
mittel
lang
On, 24 h after last