Manual Programming - Schell EDITION E 01 015 28 99 Instrucciones De Montaje

Tabla de contenido

Manual programming

Stagnationsspülung
Stagnationsspülung
lung
Spüldauer
Spüldauer
Reinigungsstopp
1 2
Reinigungsstopp
p
Geruchverschlussspülung
Geruchverschlussspülung
ssspülung
Stadionbetrieb
F1
Stadionbetrieb
Reichweiteneinstellung
Reichweiteneinstellung
F2
stellung
F3
Vorspülung
Vorspülung
**
Factory setting
** Programming example
Datum
Datum
Bemerkungen
Bemerkungen
Programming is carried out in four steps, which are briefl y
summarised here.
Start manual programming
1.
Disconnect the power supply — wait at least 20 s —
and reconnect the power supply.
1 : 1
When the electronics are booting, the LED in the
sensor fi eld fl ashes red/yellow.
Do not put your hands into the sensor area during
this phase!
Afterwards the LED is red for max. 7 s. During this
red phase, cover the sensor fi eld and keep it co-
vered. Programming mode is started.
Select function (F1 - F3)
2.
The functions are now indicated one at a time by the
fl ashing yellow LED (see table).
To select a function, uncover the sensor fi eld when
the corresponding code is fl ashing.
26
Zustand der Armatur
5 mm
5 mm
50 - 100 mm
Parameters:
Flush volume
Parameters:
Range
Stagnation fl ush
1 : 1
5 mm
Wasser läuft
Kein Wasser
Wenig Wasser
Manual programming
Operating elements for programming:
1 LED (yellow / red)
2 Sensor fi eld
The following table provides an overview of the main
programs and the available parameters for program-
ming the fi tting manually:
P1
P = Dependiendo de la presión de fl ujo (véase la tabla de la pág. 22)
P1
Short
kurz
mittel
Off *
lang
In the pictures on pages 28 and 29, manual programming is
depicted step-by-step.
As an example it is shown how to set the "range" function
(F2) to "long" (P3).
Set parameters
1 : 1
3.
The fl ashing red LED shows you the currently set
1 : 1
parameter (see table).
1 : 1
By covering the sensor fi eld again you can set the
corresponding parameter. The parameters are indica-
ted one at a time by the fl ashing red LED (see table).
To set a parameter, uncover the sensor area when
the corresponding code is fl ashing.
Start operation
4.
After leaving the sensor fi eld, the programming
mode starts once again with a time window of 7
seconds (red LED is on continuously).
If the sensor fi eld is not covered during these 7 se-
conds, the programming is completed. The fi tting is
now ready for use.
Kein Wasser
Wasser läuft
Wenig Wasser
Kein Wasser
Wenig Wasser
...
P15
...
P2
Medium *
kurz
mittel
lang
On, 24 h after last
use
1 : 1
P3
kurz
mittel
Long **
lang
On, daily
every 24 h
Tabla de contenido
loading

Este manual también es adecuado para:

Edition e 01 016 28 99

Tabla de contenido