Manual programming

50 - 100 mm
1 2
F1
F2
F3
F4
F5
F6
**
Factory setting
** Programming example
Programming is carried out in four steps, which
are briefl y summarised here.
Start manual programming
Disconnect the power supply — wait at
least 20 s — and reconnect the power
supply.
When the electronics are booting, the LED
in the sensor fi eld fl ashes red/yellow.
Do not put your hands into the sensor
area during this phase!
Afterwards the LED is red for max. 7 s.
During this red phase, cover the sensor
fi eld and keep it covered. Programming
mode is started.
Select function (F1 - F6)
The functions are now indicated one at a
time by the fl ashing yellow LED (see table).
To select a function, uncover the sensor
fi eld when the corresponding code is
fl ashing.
40
Manual programming
Operating elements for programming:
1 LED (yellow / red)
2 Sensor fi eld
The following table provides an overview
of the main programs and the available
parameters for programming the fi tting
manually:
Parameter:
Flush time
1 s
P1
Range
Short
Stagnation
Off *
fl ush
Pre-fl ushing
Off *
1 s
Stadium
Off *
mode
Odour trap
Off *
fl ushing
In the pictures on pages 42 and 43, manual pro-
gramming is depicted step-by-step.
As an example it is shown how to set the "range"
function (F2) to "long" (P3).
Set parameters
The fl ashing red LED shows you the cur-
rently set parameter (see table).
By covering the sensor fi eld again you
can set the corresponding parameter. The
parameters are indicated one at a time by
the fl ashing red LED (see table).
To set a parameter, uncover the sensor area
when the corresponding code is fl ashing.
Start operation
After leaving the sensor fi eld, the pro-
gramming mode starts once again with a
time window of 7 seconds (red LED is on
continuously).
If the sensor fi eld is not covered during
these 7 seconds, the programming is com-
pleted. The fi tting is now ready for use.
2 s
P2
Medium *
Long **
On, 24 h after
On, daily every 24 h
last use
On
On
On
3 s ..15 s
P3