GB
3.
Starting procedure
Prior to operating the blind rivet nut setting tool, attach the relevant threaded mandrel with
nosepiece to match the thread size.
3.1
How to change a threaded mandrel
•
Disconnect the blind rivet nut setting tool from the compressed air network.
•
Detach locknut 1, using double open-end spanner SW27.
•
Unscrew nosepiece 2 with locknut 1
•
Push slide 11 back all the way to buffer and hold tight
•
Unscrew threaded mandrel 3
•
Insert new threaded mandrel of same size (if worn out) or threaded mandrel of matching
thread size all the way to buffer.
•
Release slide. At the same time make sure that the threaded mandrel is locked safely
inside the hexagon socket of the slide. If required, unscrew threaded mandrel slightly until
the slide locks.
•
Insert a matching nosepiece for each thread size using locknut 1 and lock loosely with
locknut, using a double open-ended spanner.
•
Set threaded mandrel length "X", as described under item 3.2.
3.2
How to set threaded mandrel length "X"
•
Detach locknut 1, using double open-end spanner.
•
Adjust threaded mandrel length "X", according to nut length (see image 4) by turning
nosepiece 2.
•
Make full use of depth of thread for closed blind rivet nuts (image 4).
•
Secure nosepiece 2 using locknut 1
The setting stroke of the blind rivet nut setting tool is not affected by adjusting the mandrel
length.
20