5 Putting into operation
®
ABIMIG
W T
1
10
1
Torch neck
2
Insulating piece
3
Torch handle
4
Cable assembly
Fig. 3
Mounting the liner for ABIMIG
EN - 10
3 Screw down the nut again, tighten using an ABIMIG
excess length at the handle threaded part so that it protrudes 2 mm.
4 Screw down rotating or repluggable torch neck again at the handle.
For use of steel wires with divided wire guide.
2
3
40
53
5
Connection nut
6
Nut
7
Central connector
®
1 Disconnect the cable assembly (4) on the machine side and lay it out
straight.
2 Unscrew and remove the torch neck (1).
3 Unscrew the insulating piece (2) from the torch neck seat using a flat head
screwdriver (width approx. 10 mm).
4 Optionally seal the torch neck with the sealing plug (10).
5 Unscrew the nut (6) from the central connector (7).
6 Push out the liner (9) from the central connector (7) until reaching the end
stop of the liner's nipple in the torch.
7 Screw on the nut (6) hand tight.
4
9
W T torches
ABIMIG
®
wrench and cut off
5
14
8
Switch key wrench
9
Liner
10 Sealing plug
®
6
7
8