REGULAR MAINTENANCE
To make the operation easier, lift the sealing bar upwards
extracting it from the two pins
The use of a soft cloth or non-abrasive sponge and a neutral
detergent or alcohol-based disinfectant is recommended.
Finally, install the bar on the two pins
les on the lower part of the bar and check correct engagement.
ATTENTION: do not remove the black Teflon strip!
Do not use scrapers or abrasive tools!
8.1.6 OIL PUMP DEHUMIDIFICATION
The core of the machine is the vacuum pump. Carry out the following instructions to preserve the inside surfaces of the
pump from oxidation, which blocks the rotor due to oxidized residue, which occurs when the steam, sucked in together
with air, condenses and remains inside the pump body for a long time:
1) Always pack the product while it is cold, possibly at 3-4°C. The hotter the product is, the less it lasts and the more
condensation is formed inside the pump, thereby oxidizing and damaging it.
2) If the device is used only every now and then, before packing the products, carry out a vacuum chamber machine
heating cycle, pressing PUMP key. 3-4 minutes later, interrupt the cycle pressing STOP key. This allows the temperature
of the pump oil to be brought to a steady level and to evacuate the steam.
3) We recommend carrying out the dehumidification cycle of the pump oil once a week that is activated by pressing the
VAC key for 5 seconds, and closing the lid.
8.1.7 PERIODS OF INACTIVITY
If the machine is to remain at a standstill for a long period of time, clean the inside and outside thoroughly and protect
the external surfaces with specific oil-based products for stainless steel.
ATTENTION! Disconnect the plug until further use.
ATTENTION! before new use, control the integrity of the machine and clean carefully.
When re-starting, carry out an automatic dehumidifying cycle of the pump oil (§ 7.4.1).

8.1.8 MALFUNCTIONING

ATTENTION! In the case of malfunctioning, before calling the Dealer to request after-sales assistance,
check the perfect insertion of the power supply cable and make sure electricity is present.
Moreover, check that the lid gasket is well inserted and that the sealing bar is correctly engaged on the
two pins.
If, after having carried out the suggested controls, still does not work, disconnect the machine from the mains and
call the Dealer or authorized after-sales centre, communicating the machine serial number.
ATTENTION! Do not try to repair or modify any part of the appliance: as well as making the warrant null and void,
it can be potentially dangerous. Entrust specialized technicians only.