9) Refasten the drain cap at the bottom of the pump and refill the pump with oil up to the correct level: in the sight-glass,
the level of oil should be near the top line (Fig. 12).
10) Fasten the filling cap and restore the rubber seal.
11) Down and close the machine body, paying attention to position it correctly.
12) Re-install the back panel and fasten the screws.
11.4 REPLACEMENT OF EXHAUST FILTER
To reach the pump for maintenance, follow the pro-
cedure described at points from 3 to 6 in chap. 11.3.
FOR EVOX 25H - PUMP 8 MC/H
• Use pliers to undo the cap of the exhaust filter on
the body of the pump. Remove the exhaust filter
(Fig. 13-14).
• Position the new filter with o-ring and use the pliers
to screw on the new cap provided with the filter.
FOR EVOX 25 - PUMP 4 MC/H
• Remove the exhaust filter cup (A).
• Unscrew the exhaust filter (b) on the
pump body.
• Screw the new filter with the O-ring.
Down and close the machine as de-
scribed in chap. 11.3
EVOX 25h
(Pump 8mc/h)
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H
MAX
MIN
EVOX 25
A
Fig. 13
Fig. 12
(Pump 4mc/h)
Fig. 14
MAINTENANCE
b