Technical Specifications - baltur TBG 45 PN-V Manual De Instrucciones

Quemadores de gas diestado con inversor
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

TECHNICAL SPECIFICATIONS

THERMAL CAPACITY
OPERATION
NOx EMISSIONS
MOTOR
ABSORBED ELECTRICAL POWER*
line FUSE
IGNITION TRANSFORMER
VOLTAGE
PROTECTION RATING
FLAME DETECTOR
NOISE**
AMBIENT TEMPERATURE OF OPERATION
WEIGHT
Natural Gas (G 20)
FLOW RATE
PRESSURE
STANDARD ACCESSORIES
BURNER COUPLING FLANGE
INSULATING GASKET
STUD BOLTS
HEXAGONAL NUTS
FLAT WASHERS
*)
Total absorption at start with ignition transformer on and fan motor supplied at 50 Hz.
**) Noise levels measured in the laboratory of the manufacturer with burner running on test boiler, at maximum nominal thermal output.
TECHNICAL AND FUNCTIONAL SPECIFICA-
TIONS
Gas burner with low NOx and CO emissions in accordance
with "Class III" of the European standard EN676
Two-stage progressive output operation.
Ability to operate with output modulation by means of mount-
ing the automatic regulator (to be ordered separately with the
modulation kit).
Modulation ratio 1:4.
High fan output, low electrical absorption, low noise.
Combustion head with exhaust gas recirculation which allows
extremely low polluting emissions with particular attention to
nitric oxide (NOx).
TBG 45 PN-V
MAX kW
MIN kW
Modulating / Progressive two stage
< 80 (Class III according to EN 676)
mg/kWh
kW
r.p.m.
kW
230 V
26 kV - 40 mA - 230/240 V - 50/60 Hz
1N ~ 230 V + 10% - 15% - 50/60 Hz
dBA
MAX
° C
MIN
° C
kg
MAX
m³n/h
MIN
m³n/h
MAX
mbar
TBG 45 PN-V
Maintenance facilitated by the fact that the mixing unit can be
removed without having to remove the burner from the boiler.
Combustion air flow adjustment with closure of the shutter when
paused to prevent any heat dispersion to the flue.
Adjustment of the number of revolutions of the fan when the
requests by the burner vary through a frequency converter to
obtain a noticeable reduction in noise and electricity consump-
tion (only in V version).
Gas adjustment through the proportional working valve control-
led pneumatically.
Possibility to integrate the burner with a kit for valve seal control.
Equipped with 4 and 7 pole connectors, 1 flange and 1 insulating
seal for fixing to the boiler.
Gas train exit possibility from upwards or from below.
4 / 24
0006081484_201104
TBG 60 PN-V
450
600
100
120
burner
0,50
0,75
2820
2800
0,71
0,98
4 A
4 A
IP 44
IONIZATION PROBE
73
75
40
- 10
42
44
45,3
60,3
10,1
12,1
360
TBG 60 PN-V
2
2
1
1
N° 4 M 12
N° 4 M 12
N° 4 M 12
N° 4 M 12
N° 4 Ø 12
N° 4 Ø 12
Tabla de contenido
loading

Este manual también es adecuado para:

Tbg 60 pn-v

Tabla de contenido