Unloading The Tool; Application Guidelines; Care And Maintenance - Hilti GX120-ME Manual De Instrucciones

Ocultar thumbs Ver también para GX120-ME:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
7.7 Removing a jammed fastener 15
1.
Remove the magazine.
2.
Remove the nosepiece.
3.
Fit the nosepiece into the support supplied.
4.
Use the pin punch to remove the fastener.

7.9 Application guidelines

NOTE
For detailed information, please ask the Hilti marketing organization in your country for a copy of the Hilti Fastening
Technology Manual or the applicable national regulations.
Concrete
A = min. distance from edge = 70 mm (2¾")
B = min. fastener center spacing = 80 mm (3¹/₈")
C = min. base material thickness = 100 mm (4")
B
Steel
A = min. distance from edge = 15 mm (⁵/₈")
B = min. fastener center spacing = 20 mm (¾")
C = min. base material thickness = 4 mm (⁵/32")
B
7.10 Belt hook 16
The belt hook can be used to attach the tool in position
1 to a belt or in position 2 to a ladder or scaffold.

8 Care and maintenance

WARNING
The tool must be unloaded (gas can and fasteners
removed from the tool) before carrying out cleaning
or maintenance.
A
ET C
A
C

7.8 Unloading the tool

1.
Open the cover of the gas can compartment.
2.
Press the can retaining clip and remove the gas can.
3.
Close the cover of the gas can compartment.
4.
Pull the nail pusher back until it engages.
NOTE The nail pusher must engage in this position.
5.
Remove the fasteners from the magazine.
6.
Release the nail pusher in the magazine and allow it
to slide forward slowly.
CAUTION
The tool may get hot during use. You could burn your
hands. Wear protective gloves before carrying out
care and maintenance. Allow the tool to cool down.
en
21
Tabla de contenido
loading

Este manual también es adecuado para:

Gx 120

Tabla de contenido