6.2 Setting up the cable assembly

1
8
1
Connection module
2
Emergency stop cable
3
Control lead
Fig. 5
Setting up the cable assembly
4
Central connector
5
Air-blast hose
6
Connection nut
NOTICE
• Select the correct wire type and appropriate wire guide for your
application.
• For information on cutting the wire guide to size and correctly assembling
it, please see the following section:
 9 Maintenance and cleaning on page EN-17
• Spiral liners = for steel and stainless steels
• PA liners = for aluminium, copper, nickel and stainless steels
1 Lay out the cable assembly (7) straight and attach it to the connection
module (1) on the torch side.
2 Slide the cut-to-length wire guide from the central connector (4) up to the
stop in the contact tip and screw into place with the connection nut (6).
If required, connect the emergency stop cable (2) of the CAT robot mount (8)
to the cable assembly (7).
 6.4 Connecting the control lead on page EN-14
2
7
7
8
6 Putting into operation
Cable assembly
CAT robot mount
EN - 13
3
4
5
6