PROGRAMMING PROCEdURE (Setting the programmer and the current sensor)
• The installation of both anti-derailment buffers is absolutely obligatory.
• Make sure that the safety devices are at rest otherwise you will not be able to enter programming.
dip-switch settings dS
CAUTION: If you change the dip settings you must memorise
them; press the "PROG" button, "dIP" will appear on the display
indicating that the settings have been memorised.
Sequential command Td/CH
Dip 1 "ON" = Sequential command "open-close"
Travel direction inversion only during closing.
Dip 1 "OFF" = Sequential command
"open-block-close-block"
Automatic reclosing (dIP 2)
Dip 2 "ON" = Automatic reclosing enabled
Dip 2 "OFF" = Automatic reclosing disabled
Operation with one or two motors (dIP 3)
Dip 3 "ON" = Single motor operation
Dip 3 "OFF" = Double motor operation
Warning light output (dIP 4)
Dip 4 "ON" = Warning light output intermittent
Dip 4 "OFF" = Warning light output fixed
FTCI test (dIP 5)
FTCI test enabled
Dip 5 "ON" =
Dip 5 "OFF" = FTCI test disabled
If you enable the security test you will have to connect both the
transmitter and the receiver to the controlled load output (CTRL
30 Vdc). When the test is enable one second will pass between
receiving a command and carrying it out.
CURRENT SENSOR
The programmer checks the electrical input to the motor,
detecting any eventual increase in effort above the normal
operating limits and intervenes as an additional safety device.
When the sensor intervenes the door automatically inverts the
travel direction.
ON
2 3 4 5
ATTENTION! IF THE DOOR
ON
MOVES IN THE CLOSING
DIRECTION THE MOTOR
2 3 4 5
CONNECTION IS INCORRECT.
PRESS "PROG" AGAIN TO
CANCEL THE PROGRAMMING
PROCEDURE, INVERT THE
MOTOR CONNECTION (RED AND
ON
BLACK CABLE) AND REPEAT THE
2 3 4 5
PROGRAMMING PROCEDURE.
ON
WHEN THE DOOR REACHES THE COMPLETELY OPEN POSITION IT
INVERTS THE TRAVEL DIRECTION AND AFTER MOVING FOR A FEW
2 3 4 5
CENTIMETRES IT WILL OPEN AGAIN TO CONFIRM THE COMPLETELY
OPEN POSITION. AT THIS POINT THE DOOR MOVES IN THE CLOSING DIRECTION. WHEN IT IS
COMPLETELY CLOSED IT INVERTS ITS TRAVEL DIRECTION FOR A FEW
CENTIMETRES AND THEN STARTS CLOSING AGAIN SO AS TO ESTABLISH THE
ON
COMPLETELY CLOSED POSITION.
2 3 4 5
AFTER HAVING CARRIED OUT THIS MANOEUVRE THE LOGIC CONTROL WILL OPEN THEN
CLOSE THE DOOR COMPLETELY IN ORDER TO CALIBRATE THE CURRENT SENSOR.
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL HAVE
TO REPEAT THE
PROGRAMMING PROCEDURE.
23
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE "PAUSE" SYMBOL
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
PRESS PROG
THE PAUSE TIME COUNT
WILL START (MIN. 2
SECONdS: MAx 20
SECONdS) INDICATED BY
THE "PAUSE" SYMBOL
FLASHING ON THE DISPLAY
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE DOOR OPENS
SLOWLY IN ORDER TO FIND
THE COMPLETELY OPEN
POSITION.
WHEN THE DOOR REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE
...4... sec.