Zodiac WH000508 Guia De Inicio Rapido página 10

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
7
Troubleshooting
• Before you contact the retailer, carry out these few simple checks if a problem occurs. If the
problem is not resolved, contact your retailer.
: Actions to be performed by a qualified technician only.
Appliance behaviour
The appliance does not
start heating straight
away
The appliance is
discharging water
The evaporator is iced
over
The appliance is
''smoking''
The appliance is not
working
The fan is running but
the compressor stops
from time to time with
no error message
The appliance is
working but the water
temperature does not
increase
The appliance trips the
circuit breaker
10
• When the water flow rate is zero or is not enough, the appliance stops: check that the
water is circulating correctly in the appliance and that the hydraulic connections are
correct.
• The appliance stops when the outdoor temperature falls below -7 °C.
• To check that the water is not coming from a leak in the pool circuit on the appliance,
shut it down and run the filter pump to circulate water in the appliance. If the water
continues to flow through the condensate drainage lines, there is a water leak in the
appliance: contact your retailer.
• The appliance will soon switch to its defrost cycle to melt the ice.
• If the appliance cannot manage to defrost its evaporator, it will stop itself; this means
that the outdoor temperature is too low (below -7°C).
• If the appliance is not in its defrost cycle, this is not normal. Switch off and disconnect
the appliance immediately and contact your retailer .
If there is no display, check the supply voltage and the F1 fuse.
• When the water flow rate is zero or is not enough, the appliance stops: check that the
water is circulating correctly in the appliance.
• If the outdoor temperature is low, the appliance will perform defrost cycles.
• The appliance is unable to capture enough calories as its evaporator is clogged with
dirt. Clean it to restore its performances.
• The operating mode is not powerful enough (appliance in ''SILENCE'' or ''SMART''
mode). Switch to ''BOOST'' mode and set the filtration to 24/24 manual while the
temperature rises.
• Check that the automatic filling valve is not stuck in open position; this will keep
supplying cold water into the pool and will prevent the temperature from rising.
• There is too much heat loss as the air is cool. lnstall a heat insulated cover on the pool.
• The appliance is unable to capture enough calories as its evaporator is clogged with
dirt. Clean it to restore its performances.
Check that the appliance is the right size for this pool and its environment.
Check that the circuit breaker is correctly dimensioned and that the cable section
used is correct.
The supply voltage is too low; contact your electricity supplier .
Characteristics
Refer to the online manual for
further details about error codes
display, LEDs behaviour on the
printing circuit board and the wiring
diagrams.
loading

Este manual también es adecuado para:

Z350iq md6Z350iq md5Z350iq md4Z350iqWh000509Wh000507