Mains voltage
Power
Standby consumption
Battery types
Battery capacity
Charging current
Charging voltage range
Low voltage detection
Device type
Mains lead
Charging cable
Degree of protection
Protection class
Operating temperature
Storage temperature
Dimensions
Weight
Connecting a battery
Attention!
Prior to first use, check that the mains voltage
and frequency of the charger (220-240 V
50 Hz) indicated on the type plate match the
corresponding data of the mains supply. Always
connect the clamps first, before connecting the
device to the power.
1. Before commencing charging, check that the bat-
tery voltage and battery type match the specified
information of the charger (see the next section:
Charging modes and first use).
2. Connect the red charging clamp (positive) to the
battery's positive terminal (+, P, Pos).
3. Fasten the black charging clamp (negative) to the
battery's negative terminal (-, N, Neg).
4. After the clamps are connected to the battery,
connect the mains cable to a suitable socket.
16
Technical data
220-240 V AC 50 Hz 1300 mA
90 watt
< 1 W
Wet, gel, MF/maintenance-free, AGM, CA, VRLA, EFB, LiFePO4 (4-cell)
18-240 Ah (12 V lead-acid battery)
10-120 Ah (24 V lead-acid battery)
10-80 Ah (12.8 V lithium battery)
7.5 A (12 V lead-acid battery)
3.75 A (24 V lead-acid battery)
5.0 A (12.8 V lithium battery, 13.6 V power supply)
2.0-14.0 V (12 V lead-acid battery)
14.0-28.0 V (24 V lead-acid battery)
11.6-13.8 V (12.8 V lithium battery)
2 V (12 V battery)
14 V (24 V battery)
Intelligent 10-stage charger
180 cm with Euro plug
180 cm with terminal clamps (red = positive, black = negative)
IP65 (dustproof and splashproof)
II
0 °C...+30 °C
-30 °C...+60 °C
234x104x64 mm
1340 g
5. Once charging is complete, carry out the pro-
cess in the reverse sequence. First disconnect
the mains cable from the power, then the black
charging clamp (negative) and then the red
charging clamp (positive).
Charging modes and first use
The charger has eight charging modes. Only
operate the charger, once you have checked which
charging mode is suitable for your battery.
1. The device automatically switches to standby
mode when you connect the charger to the
mains. No charging by the charger occurs in
standby mode and the power supply to the bat-
tery is interrupted.
2. Pressing the mode button [8] switches to normal
mode. The charger checks the battery voltage
and automatically detects whether a 12 V or
24 V battery is connected. Charging starts au-
tomatically.