Ferroli EGEA TECH 90 LT Manual De Uso, Instalación Y Mantenimiento página 157

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
EGEA TECH
6.10
COMMISSIONING
To commission the device, perform the following operations.
6.10.1 Preliminary checks
Check that the device has been
connected to the ground cable.
OBLIGATION
Check that the line voltage cor-
responds to that indicated on the
device plate.
ATTENTION
Check that the device is free from
tools or utensils of various kinds.
VISUAL IN-
If present, remove them.
SPECTION
6.10.2 General cleaning
Do not pour or spray water on
the product.
Do not clean the surfaces with
PROHIBITION
easily flammable substances
(for example: alcohol or paint
thinners).
Clean only the external surface
using a soft and dry cloth.
MANUAL
CLEANING
6.10.3 Commissioning of the plant
• Fill the tank completely via the inlet faucet and check that
there are no water leaks from gaskets and connections.
• Do not exceed the max. permissible pressure indicated in
the "general technical data" section.
• Check the water circuit safety devices.
• Plug the unit into the power outlet.
• When the plug is inserted, the unit is OFF.
To turn on the unit, refer to paragraph "2.5.1 Power on" on
page 123
In case of a sudden power outage, when restored the equip-
ment will restart from the operating mode prior to the interrup-
tion.
90 LT - 120 LT
cod. 3540000400 - Rev. 03 - 09/2023
6.10.4 Query, editing operating parameters
This
equipment
has
ing
and
modifying
For details, refer to chapter "2. USE OF THE WATER HEAT-
ER" on page 121.
NB!: Use of the password is reserved for qual-
ified personnel; any consequences due to
incorrect parameter settings will be the sole
responsibility of the customer. Therefore,
any interventions requested by the custom-
er from an authorised technical assistance
centre FERROLI S.p.A. during the standard
warranty period, for product problems due to
incorrect settings of password-protected pa-
rameters, will not be covered by the standard
warranty.
7.
REPLACEMENTS
Incorrect repairs may put the
user in serious danger. If your
device needs any repair, con-
ATTENTION
tact the technical assis-
tance service.
Any intervention on the de-
vice, including disposal, must
be performed by qualified per-
sonnel with a suitable Refrig-
eration Technician's Licence
aimed at the knowledge and
EXPERT
R290
TECHNI-
management of systems con-
CIAN
taining HC type gases such as
R290 (Propane).
Before undertaking any main-
tenance operation make sure
the equipment is not and can-
ATTENTION
not accidentally be electrically
powered.
Therefore, turn off the de-
vice and remove the plug
from the socket.
distinct
menus
for
the
operating
parameters.
EN
consult-
157
loading

Este manual también es adecuado para:

Egea tech 120 lt