TECHNICAL FEATURES
Models
General data
Tank
* Data declared according to the UNI EN 12897:2020
standard (Ambient air temperature = 20°C, water
temperature in the storage tank = 65°C)
** according to European regulation 812/2013
Heat pump electrical data
Electric heater electrical data
Electrical data Heat pump + electric heater
Air circuit
Refrigerant circuit
Data according to EN 16147: 2017 standard for
AVERAGE climate (unit in ECO mode,
Hot water setpoint = 53 ° C; Inlet water = 10 ° C;
Inlet air temp = 7 ° C DB / 6 ° C WB)
* according to European regulation 812/2013
Data according to EN 12102-2: 2019 ECO mode
with Inlet air temp = 7 ° C DB / 6 ° C WB
EN
148
Voltage supplie
Tank water content - Vnom
Maximum inlet water pressure
Empty weight
Operating weight
Dimensions (fxh)
Max. Hot water temperature with heat pump
Max. Hot water temperature with additional
electric heater
Material
Cathodic protection
Insulating type
Insulation thickness
Heat loss *
Heat loss after 24 hours*
Specific heat loss*
Insulation class**
Average power input in heating
Maximum power input
Maximum current input
Supply voltage
Power input
Current input
Maximum power input
Maximum current input
Fan type
Air flow rate
Maximum available pressure head
Ducts diameter
Compressor
Refrigerant
Refrigerant charge
Evaporator
Condenser
Load profile
Water heating energy efficiency class *
Water heating energy efficiency - h
COP
DHW
Maximum volume of mixed water at 40 °C - V
Reference hot water temperature - θ'
Rated heat output - Prated
Heating up time - t
h
Annual electricity consumption - AEC
Stand-by power input (P
)
es
Indoor sound power level
Outdoor sound power level
cod. 3540000400 - Rev. 03 - 09/2023
EGEA TECH
90 LT
230Vac-50Hz
89
0,7
49
138
501 x 1303
62
75
Enameled steel
Mg rod anode
Polyurethane
50
40
0,96
0,89
B
270
380
1,74
230Vac-50Hz
1200
5,2
1580
6,95
Centrifugal
170
110
125
Rotary
R290
0,15
Copper-aluminum finned coil
Aluminum tube wound outside tank
M
A+
123
wh
2,88
102
40
49,3
wh
0,607
05:52
419
22
54
45
90 LT - 120 LT
U.m.
120 LT
-
118
l
0,7
MPa
55
kg
173
kg
501 x 1555
mm
62
°C
75
°C
-
-
-
50
mm
46
W
1,10
kWh/24h
1,02
W/K
B
-
270
W
380
W
1,74
A
1200
W
5,2
A
1580
W
6,95
A
-
170
m
/h
3
110
Pa
125
mm
-
-
0,15
kg
-
-
M
-
A+
-
112
%
2,62
-
145
l
50,4
°C
0,613
kW
08:15
h:min
458
kWh
26
W
54
dB(A)
45
dB(A)