Cleaning
 Insert a charged rechargeable battery of the same
type, observing the polarity.
 Place the cover onto the rechargeable battery
compartment.
 Press the cover on gently.
 Fasten the cover with the screw.
42
Cleaning
ATTENTION!
Material damage possible due to
incorrect cleaning.
 Clean the TORSIOTRONIC
dry, clean cloth only.
Repair, maintenance and
calibration
The TORSIOTRONIC
®
for regular calibration according to the specifications
of DIN EN ISO 6789.
The internal components of the TORSIOTRONIC
are subject to normal wear during use. The
accuracy of the triggering values therefore has to be
checked at regular intervals.
Repairing the TORSIOTRONIC
In the event of damage to the TORSIOTRONIC
malfunctions, repair with subsequent calibration is
necessary.
Repairs may only be carried out by STAHLWILLE.
Service portal: service.stahlwille.de
Notes on calibration
Calibration or adjustment of the TORSIOTRONIC
may only be performed using a suitable calibration
device.
TORSIOTRONIC
devices are test equipment. The
®
calibration interval is dependent on the following
operating factors, etc.:
 Required accuracy
 Frequency of use
using a
®
is maintenance-free except
®
®
or
®
®
loading