Using the TORSIOTRONIC®
Manually saving fastening values
The bolting values can only be saved manually in
"Track" and "Peak" function modes.
"On" must be selected under saving in the
"Configuration" menu, see page 26.
Proceed as follows to save the bolting values
manually:
After the tightening procedure in "Track" or "Peak"
function mode, press the OK button.
The torque last applied is shown on the display.
Press the OK button again as long as the torque
value is displayed.
A short audible signal is heard. The value has been
saved.
Correcting and saving exceeded torque
If a threaded connection has unintentionally been
tightened with excessive torque, proceed as follows:
Loosen the threaded connection.
Press the OK button after loosening.
The torque last applied is shown on the display.
Press the OK button again.
A short audible signal is heard. The value has been
saved.
WARNING
Risk of injury due to damaged bolts or
workpieces.
Before tightening the threaded
connection again, check the bolt and
the workpiece for damage.
If in doubt, use a new bolt.
Tighten the threaded connection again.
The release torque stored in the software on the PC
is displayed in negative form.
37