ENGLISH
Mount the nozzle as follows:
1) close the gas tap and disconnect the flexible coupling (a);
2) disconnect the gas valve (b) from the mixer (c) unscrewing the
four screws;
3) insert the nozzle for the LPG (d) inside the seal (e);
4) proceed to mount the various components while taking care to
correctly position the seals seal (e, f);
5) when assembly is complete, switch on the equipment.
On ignition carry out a check on the gas circuit seal and also check
that the oxygen values (O
%) at maximum and minimum powers
2
come within the tolerances indicated in the table below.
METHANE TO LPG CONVERSION
WARNING:
ONCE THE CONVERSION HAS BEEN PERFORMED,
APPLY THE "LPG" LABEL (h) PROVIDED TO THE
BURNER CLOSE TO THE TECHNICAL PLATE
O
values set for working with methane and LPG
2
Methane
L.P.G.
9
O
measured with oven at 100° C
Fuel
2
as for Thermal output minmax
5.0% - 0.3
5.5% - 0.3
(g).
5.0% - 0.3
5.5% - 0.3