SETUP
Secondary voltage (double pulsed)
22
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during the various pulsation phases.
Minimum
-5.0
Pulsed slopes (double pulsed)
23
EN
Minimum
1 %
Bilevel (4T - crater filler)
24
Permits adjustment of the secondary wire speed in the bilevel welding mode.
By pressing and releasing it quickly again, "
Minimum
1 %
Initial increment
25
Allows regulation of the wire speed value during the first "crater-filler" welding phase.
Makes it possible to increase the energy supplied to the part during the phase when the material (still cold) requires
more heat in order to melt evenly.
Minimum
20 %
Crater filler
26
Allows regulation of the wire speed value during the weld closing phase.
Makes it possible to reduce the energy supplied to the part during the phase when the material is already very hot,
thus reducing the risk of unwanted deformations.
Minimum
20 %
Initial increment time
27
Lets you set the initial increment time.
Lets you automate the "crater filler" function.
Minimum
0.1 s
Crater filler time
28
Lets you set the "crater filler" time.
Lets you automate the "crater filler" function.
Minimum
0.1 s
Spot welding
30
Allows you to enable the "spot welding" process and establish the welding time.
Minimum
0.1 s
Pause point
31
Allows you to enable the "pause point" process and establish the pause time between one welding operation and
another.
Minimum
0.1 s
Maximum
Default
+5.0
0/syn
Maximum
Default
100 %
50 %
" is used again, and so on.
Maximum
Default
200 %
0/off
Maximum
Default
200 %
120 %
Maximum
Default
200 %
80 %
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
" can be used.