INSTALLATION
Connect the TIG torch coupling to the torch socket of the power source. Insert the plug and turn clockwise until all parts are
secured.
Separately connect the torch gas hose connector to the gas main.
The protection gas flow can be adjusted using the tap normally found on the torch.
Connect the water pipe (red coloured) of the torch to the inlet quick connector (red coloured - symbol
EN
Connect the water pipe (blue coloured) of the torch to the outlet quick connector (blue coloured - symbol
unit.
2.4.3 Connection for MIG/MAG welding
Connect the MIG/MAG torch to the central adapter, ensuring that the fastening ring is fully tightened.
Connect the water pipe (red coloured) of the torch to the inlet quick connector (red coloured - symbol
Connect the water pipe (blue coloured) of the torch to the outlet quick connector (blue coloured - symbol
unit.
Connect the power cable to the positive pole of the terminal strip to change polarity (see"Changing the welding polarity").
Connect the signal cable to the connector on the front of the power source.
Connect the gas hose from the cylinder to the rear gas connection. Adjust the gas flow from 5 to 15 l/min.
Connect the earth clamp to the negative socket (-) of the power source. Insert the plug and turn clockwise until all parts are
secured.
Torch socket
1
Power cable
2
Positive power socket (+)
3
Signal cable
4
Connector
5
Earth clamp connector
1
Negative power socket (-)
2
62
) of the cooling unit.
) of the cooling
) of the cooling unit.
) of the cooling