voestalpine bohler welding URANOS NX 2200 PMC Manual De Instrucciones página 83

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 210
Voltage - Arc length
7
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Synergic mode
Minimum
Maximum
-5.0
+5.0
Manual mode
Minimum
Maximum
5.0 V
55.5 V
Pre-gas
10
Allows you to set and adjust the gas flow prior to striking of the arc.
Permits filling of the torch with gas and preparation of the environment for welding.
Minimum
Maximum
0/off
99.9 s
11
Permits adjustment of the wire feed speed in the phases prior to arc striking.
Minimum
Maximum
10 %
100 %
Motor slope
12
Allows you to set a gradual transition between the sparking wire speed and the welding wire speed.
Minimum
Maximum
0/off
1.0 s
Burn back
15
Permits adjustment of the wire burn time, preventing sticking at the end of welding.
Permits adjustment of the length. Permits adjustment of the length of the piece of wire outside the torch.
Minimum
Maximum
-2.00
+2.00
Post-gas
16
Minimum
Maximum
0/off
99.9 s
Duty cycle (double pulsed)
19
Permit adjustment of the duty cycle in double pulse.
Minimum
Maximum
10 %
90 %
Double Pulsed MIG welding
20
Allows regulation of the pulsation amplitude.
Minimum
Maximum
0 %
100 %
Minimum
Maximum
0.5 m/min
22 m/min
Pulse frequency (double pulsed)
21
Allows regulation of the cycle, i.e. of the impulse repetition cycle.
Allows the impulse frequency to be regulated.
Minimum
Maximum
0.1 Hz
5.0 Hz
Default
0/syn
Default
5.0 V
Default
0.1 s
Default
50 %
Default
0/off
Default
0/syn
Default
2.0 s
Default
50 %
Default
±25 %
Default
2.5 m/min
Default
2.0 Hz
79
SETUP
EN
Tabla de contenido
loading

Tabla de contenido