board) with the contacts pointing down-
wards. See
figure
18.
7.8 Fitting the cover
Insert and cover with integrated foam seal
1.
and push securely into place. See
19.
Secure with 4 screws (5x22) to a torque of
2.
3-3.5 Nm (1). On the ghost ONE ERK
version, also secure with 3 screws (5x22)
around the folding cover of the socket (2).
See
figure
20.
Attaching the user seal (ghost ONE ERK
version)
n
Seal one of the screws on the cover using
the user seal supplied. See
Note
The manufacturer's seal must not be
damaged. Otherwise the official calibration
conformity is void.
Attaching the lock/lead seal
n
Either attach the lead seal to the clip or fit
the lock. See
figure
21.
Attaching the decorative cover
Remove the protective film from the front
1.
panel.
Fit the decorative cover at the top (1) and
2.
press firmly onto the housing (2) until the
latches audibly engage. See
Secure the decorative panel from below
3.
with a screw (4x13) to a torque of
1.2-2 Nm. See
figure
23.
36
8 Commissioning
During initial commissioning and at the spe-
cified maintenance intervals, a test complying
with DIN VDE 0100 or the applicable national
regulations must be carried out.
figure
Note
For production reasons, the reading on the inte-
grated energy meter is not at 0 kWh.
8.1 Performing the service con-
figuration
ATTENTION
Wallbox with errors
A Wallbox with active errors is not fully func-
figure
20.
tional. There is an active error if the operating
status LED (4) is lit in red, yellow or blue.
Note
The service configuration should be carried out
when not connected to a vehicle.
Switching on the wallbox
The Wallbox is switched on as soon as the
power supply is connected.
The LEDs light up in turn as follows:
n
All LEDs red for one second
n
All LEDs white for one second
n
Charge level LED and error status LED
white
figure
22.
All other LEDs are not lit.
8 Commissioning
Note
If a vehicle is connected, the charge level
LED may be a different colour.
See
figure
24:
1
Network connection LED
2
Brightness sensor
3
Charge level LED
4
LED for operating/error status with inte-
grated button
5
Cloud/backend/HEMS connection LED
6
RFID sensor with integrated LED
7
Socket (ghost ONE ERK version only)
Incorrect installation
If the LED (4) for the operating status is lit in
blue, yellow or red, the installation is incorrect
or there is an error on the Wallbox.
Colour
Meaning
Blue
Charging a vehicle is possible,, but
one or more comfort functions are
not available.
Blue, fla-
Wallbox is still in production mode
shing
and may not be started up by the
end user.
Yellow
Charging a vehicle is not possible,
errors can be fixed without sub-
sequently resetting the Wallbox.
Red
Charging a vehicle is not possible.
After fixing the errors, the Wallbox
must be restarted.