7.3 Connecting the vehicle cable
DANGER
Risk of death due to electric shock
Contact with live parts results in a direct risk of
death due to electric shock.
n
In case of emergency or when fixing errors
or carrying out electrical work on the Wall-
box, comply with the following safety
rules:
Disconnect the Wallbox from the vol-
n
tage supply.
n
Ensure that there is no voltage.
n
Secure against being switched on
again.
n
Earth and short-circuit the Wallbox.
n
Cover any adjacent live parts and
secure the danger area.
DANGER
Risk of death due to incorrect connection
If the electrical supply line is incorrectly connec-
ted, there is a direct risk of death due to electric
shock.
Observe the wiring diagram.
n
n
Assign the wire colours correctly.
n
Observe local regulations.
1.
Slide the anti-kink protector over the
cable. See
figure
7.
2.
Insert a nut (M25).
3.
Run the anti-kink protector including cable
through from top to bottom until it meets
34
the insulation.
4.
Securely attach the nut (M25) to the Wall-
box with a fork wrench. See
5.
Connect the CP cable in the top right (sin-
gle pole terminal in future). See
6.
Insert and connect the 5 wires of the
vehicle cable in the connecting terminals
as follows:
1.
L3 (grey)
2.
L2 (black)
3.
L1 (brown)
4.
Neutral (blue)
5.
PE (green/yellow)
See
figure
10.
7.
Detach the strain relief clamp from the
component bracket (1). See
8.
Securely tighten the strain relief clamp
with the appropriate screws (4x17) using
a screwdriver (or cordless screwdriver) to
a torque of 1.65 Nm +-8% (2). See
11.
7.4 Connecting the infrastructure
cable
figure
8.
DANGER
figure
9.
Risk of death due to electric shock
Contact with live parts results in a direct risk of
death due to electric shock.
n
In case of emergency or when fixing errors
or carrying out electrical work on the Wall-
box, comply with the following safety
rules:
n
Disconnect the Wallbox from the vol-
tage supply.
n
Ensure that there is no voltage.
n
Secure against being switched on
again.
figure
11.
n
Earth and short-circuit the Wallbox.
n
Cover any adjacent live parts and
secure the danger area.
figure
DANGER
Risk of death due to incorrect connection
If the electrical supply line is incorrectly connec-
ted, there is a direct risk of death due to electric
shock.
n
Observe the wiring diagram.
n
Assign the wire colours correctly.
n
Observe local regulations.
Note
n
When connecting the infrastructure cable,
observe the wiring diagram, see
and
figure
14.
7 Installation
figure 13