KATEK ghost ONE Basic Manual De Instrucciones página 38

Ocultar thumbs Ver también para ghost ONE Basic:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
7  Installation
The Wallbox can be connected with 1 phase or 3
phases, see
Connecting the infrastructure
cable.
1.
Strip the insulation from the wires to a
length of 12 mm. See
figure
1
L2
2
L3
3
PE
4
Neutral
5
L1
2.
For 3-phase connection: Assign the
colours correctly and insert in the connec-
ting terminals from left to right in the fol-
lowing sequence (see
figure
1.
PE (green/yellow)
2.
Neutral (blue)
3.
L1 (brown)
4.
L2 (black)
5.
L3 (grey)
3.
For 1-phase connection: Insert in the
connecting terminals from left to right in
the following sequence:
For a TT/TN mains supply (see
1.
PE (green/yellow)
2.
Neutral (blue)
3.
L1 (brown)
For a IT mains supply:
1.
PE (green/yellow) in terminal 1
(green/yellow)
2.
L1 (brown) in terminal 2 (blue)
3.
L2 (black) in terminal 3 (brown)
4.
Tighten the screws on the front to a torque
of 1.65 Nm +-8%.
Setting the power supply mains con-
figuration
12.
n
Set 1-phase or 3-phase charging using the
right DIP switch.
Flip the right DIP switch up or down using
tweezers. See
Note
The left DIP switch is reserved for future
applications and must be permanently in
the "Off" position.
DIP switch
13):
On (up)
Off (down)
Setting the charging current
Set the charging current for the Wallbox
n
according to the building's line fuse pro-
tection and the rated power of the Wallbox
on the rotary switch using a 0.3 x 2 mm
screwdriver. See
figure
14):
Position
F
E
D
C
B
figure
15.
7.5 Connecting the Ethernet cable
Meaning
(optional)
1-phase
3-phase
7.6 Connecting an external control
cable (optional)
figure
16.
Value
32 A
30 A
7.7 Inserting the SIM card (optional)
25 A
A SIM card is required for an LTE connection.
20 A
16 A
Position
Value
A
15 A
9
13 A
8
10 A
7
8 A
6
6 A
2 and 3
To reset the Wallbox to the
factory default settings
All other
Reserved for future app-
positions
lications
Fit the ethernet cable in the clip pro-
n
vided (2) and insert into the port from
below (3). See
figure
17.
n
Connect the external control cable at the
designated terminals (4) (see
Left terminal (black)
Negative
Right terminal (orange) Positive
n
Insert the SIM card in the corresponding
slot on the top of the circuit board (COM
figure
17).
35