Dip-switch
The basic functions of the outdoor stations
the dip switches at the top
right:
dip 1:
Switch for setting the outdoor station as the master or
slave. When set to 1 (on): the outdoor station is configured
as the "master" outdoor station; in every system, only one
outdoor station configured as "master" is necessary; the
outdoor station supplied in the one-family and two-family
kits is configured as the "master" by default. Any additional
outdoor stations must be configured as "slave", with the
value 0 (off).
Default value: 1
dip 2-3: Pair of switches to configure the outdoor station ID; the
outdoor station supplied in the one-family and two-family
kits is configured as outdoor station "1" by default, by
setting the dip switches to the value 00 (sw2→0, sw3→0).
Any additional outdoor stations must be assigned the ID 2
(10: sw2→1, sw3→0), ID 3 (01: sw2→0, sw3→1) or ID 4
(11: sw2→1, sw3→1).
Default values: 00
dip 4-5: Pair of switches to configure the use of the push buttons:
the outdoor station supplied in the one-family kits is
configured by default for the use of 1 (one) push button,
using the value 00 (sw4→0, sw5→0); the outdoor station
supplied in the two-family kits is configured by default
for the use of 2 (two) push buttons, using the value 10
(sw4→1, sw5→0); for systems with 3 or 4 apartments, set
the value 01 (sw4→0, sw5→1).
Default values: 00 for one-family system; 10 for two-family
system.
dip 6:
Switch to assign the activation of the lock powered or of the
relay to the door release button on the front of the indoor
unit and to the lock release button on the outdoor station.
If switch 6 is "1" (ON), the defined lock is the relay; if switch
6 is "0" (OFF), the defined lock is the powered one.
Switch 6 is configured to "OFF" by default, i.e. the powered
lock is the default lock.
Reset push button:
The reset push button performs a factory reset of the outdoor station,
i.e. it returns the outdoor station back to its original factory setting.
The factory reset of the outdoor station is performed by long pressing
the reset push button (approx. 5s). The activation of the reset is
confirmed by a beep.
Note: if it is necessary to perform a factory reset on the entire
video door entry system, we recommend the following procedure:
1) Perform a Factory Reset of the slave indoor station
2) Perform a Factory Reset of the master indoor stations
3) Update the dip switch configuration relating to the outdoor
stations, if necessary
4) Perform an ordered Factory Reset of the outdoor stations,
from the outdoor station with ID "1" onwards.
5) Wait 1 minute
The outdoor station is also equipped with an NFC tag reader
Mifare keys art. 40169, 01598 and
To use
NFC keys,
configure the
has been connected and powered.
Configuration of NFC keys is specific and should be carried out for
each outdoor station.
Configuring the administration keys
1)
With the front not installed, quickly press the reset button on the
outdoor station twice: the device will respond with a sequence
of 4 beeps. The configuration procedure begins from this
moment and is signalled by the slow flashing of the name plate
backlighting LEDs; any previous configurations are deleted.
Alternatively, you can launch the configuration procedure
from the administration menu of an indoor station, see
"Installer settings": in this case, any previous key configuration
(administrator and user) will not be deleted until you proceed to
the next step 2. In this case too, the key programming status is
signalled by the slow flashing of the backlighting LEDs, and it
lasts about 30 s.
can be configured with
01817.
RFID reader after the outdoor station
2) Bring the first key up to the RFID reader; the device will emit a
long beep; the first key is configured as "administration key for
addition".
We recommend marking the key with "key for addition"
3) Bring the second key up to the RFID reader; the device will emit
a long beep; the second key is configured as "administration key
for removal".
We recommend marking the key with "key for removal".
The administration keys and all user keys can be reset by
repeating the above procedure from the beginning.
4) If no other action is carried out, the registration procedure will
end after 30 seconds with a warning tone (4 beeps).
Any new configuration of the administrator keys and user keys will be
possible, repeating the above procedure from the beginning.
The front case can now be installed on the outdoor station, taking
care to close the anti-tamper key.
Adding a user key
For the addition and removal of user keys, the front of the outdoor
station does not necessarily have to be opened. These operations
can also be carried out after the first-time system installation.
1) Bring the "administration key for addition" up to the RFID reader:
the device will beep
2) Bring an unprogrammed key up to the reader. The device
will enable it as a "user key". The device will beep when the
configuration is complete.
3) Repeat step 2) to add any other keys.
4) The procedure for enabling user keys will terminate after about
5s of inactivity.
The device will beep 4 times and stop flashing
of the procedure.
The keys added using this procedure will immediately be available
for the activation of locks, as specified below.
Removing user keys
A user key can only be removed using the actual key itself, as
specified below.
1) Bring the "administration key for removal" up to the RFID reader;
the device will beep.
2) Bring a user key up to the reader. The device will disable it. The
device will beep when the configuration is complete.
3) Repeat step 2) to remove any other keys.
4) The procedure for disabling user keys will terminate after about
5s of inactivity.
The device will beep 4 times to indicate the end of the procedure.
Powered lock
activation (Lock1)
Bring a user key up to the RFID reader for less than 2s: the lock will
be activated after one beep.
Relay activation
(Lock2)
Bring a user key up to the RFID reader for longer than 2s: the
relay will be activated after an initial notification beep
confirmation beep.