Hilti VC 5-A22-L Manual De Instrucciones Original página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
All manuals and user guides at all-guides.com
3.4
Items supplied
Dry vacuum cleaner complete with filter element, suction hose with connectors, hand nozzle, crevice nozzle,
shoulder strap and operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or online at:
www.hilti.group | USA: www.hilti.com
3.5
Li-ion battery state of charge display
The state of charge of the Li-ion battery and malfunctions of the appliance are indicated by the display on
the Li­ion battery. The state of charge of the Li­ion battery is displayed after pressing one of the two battery
release buttons.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED blinks, the appliance is ready for use.
1 LED blinks, the appliance is not ready for use.
4 LEDs blink, the appliance is not ready for use.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch.
If the battery charge state LEDs blink, please refer to the information given in the Troubleshooting
section.
3.6
Indication of overloading and overheating
The power tool is equipped with an electronic system to protect against overloading and overheating. The
power tool switches itself off automatically in the event of overloading or overheating. After releasing the
control switch, the power tool may not restart immediately when the switch is pressed again (while the power
tool is cooling down).
4
Technical data
Rated voltage (DC)
Rated current input
Ambient temperature
Storage temperature
Maximum partial vacuum
Maximum volumetric flow rate (air)
4.1
Noise and vibration information, measured in accordance with EN 60335-2-69
Sound pressure level (L
Sound power level (L
Uncertainty
Vibration emission value (a
Uncertainty (K)
2202256
*2202256*
Printed: 30.01.2018 | Doc-Nr: PUB / 5397505 / 000 / 00
)
pA
)
WA
)
h
Meaning
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
The battery has overheated.
The appliance has overheated or is overloaded.
VC 5-A22-L
21.6 V
16 A
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
11 kPa
35 ℓ/s
VC 5-A22-L
70.9 dB(A)
85.2 dB(A)
2.4 dB(A)
< 2.5 m/s²
Is taken into account in
the stated value
English
15
loading