2.4 I Connection of the condensates drain line
An condensates connection is present in the appliance, consisting in a 3 pieces PVC connection Ø32 mm to glue.
Condensate drainage outlet: Ducted machines.
• This PVC connection has to be conducted to a water drain pipe fitted with a U-tube system
or syphon, that has to include a draining plug for easy removal of any debree.
• Make sure that the U-tube system or syphon is designed properly and completely filled with
water to avoid air entering the condensation tray, thus preventing a correct evacuation of
the condensation water.
• The angle of this drain line should be sufficient to ensure a correct water flow.
Tip: condensate drainage
Caution, several litres of water can be drained from your appliance each hour.
We strongly recommend connecting the drain to a suitable water drainage system.
2.5 I Access to the electrical connection terminal blocks
16
Condensate drainage outlet: Through the wall machines.
1/4 turn
loading