clage DSX Touch Instrucciones De Uso página 49

Ocultar thumbs Ver también para DSX Touch:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 148
2. Technical specifications
Model
Energy efficiency class
Rated capacity / rated current
Chosen capacity / current
Nominal voltage
Electrical connection
Min. required cable size
1)
Hot water (l/min)
2)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required spec. water resistance
Spec. electrical conductivity
Inlet temperature
Required flow rate to switch on
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
Transmission and receiving frequency
range Wi-Fi
Transmission power Wi-Fi
Transmission and receiving frequency
range Bluetooth
Transmission power Bluetooth
Radiation
Transmission range
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013.
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature
18 kW /
16.2 kW /
21 kW /
26 A
25 A
400 V
380 V
400 V
4.0 mm
2
9.2
8.3
6.8
6.1
0.08 bar at 1.5 l/min
in electrical connection from above.
2
49
DSX TOUCH
A *
)
18 kW..27 kW (26 A..39 A)
19 kW /
24 kW /
30 A
29 A
35 A
380 V
400 V
3~ / PE
4.0 mm
6.0 mm
2
10.7
9.7
12.3
7.9
7.2
9.0
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 70 °C
1.5 l/min – automatic
1.3 bar at 9.0 l/min
20 – 60 °C [70 °C]
G ½ inch
4.5 kg
2.412 – 2.472 GHz (802.11b/g/n)
≤ 100 mW
2.4 – 2.4385 GHz
≤ 8 mW
undirected
10 meter incl. barrier
I
IP25
CLAGE
21.7 kW /
27 kW /
24.4 kW /
33 A
39 A
37 A
380 V
400 V
380 V
6.0 mm
2
2
11.1
13.8
12.5
8.2
10.2
9.2
®
3)
EN
loading