Dimensions, length x width x height (including foot)
Weight with foot and including batteries
5
Operation
5.1
Inserting/changing batteries
•
Make sure that battery polarity is correct.
•
Changes all the batteries at the same time.
•
Use only batteries that have been manufactured in accordance with international standards.
1. Flip the battery compartment open.
2. Remove the spent batteries, if applicable.
3. Insert the new batteries.
4. Close the battery compartment.
5.2
Fall arrest
WARNING
Risk of injury by falling tool and/or accessory!
▶ Use only the Hilti anti-fall cable recommended for your product.
▶ Prior to each use, always check the anti-fall cable and the attachment points of the anti-fall cable for
possible damage.
Comply with the national regulations for working at heights.
As drop arrester for this product, use only the Hilti PMA 92 anti-fall cable.
▶ Secure the anti-fall cable to the laser and to a load-bearing structure. Check that it holds securely.
Comply with the operating instructions of the Hilti anti-fall cable.
5.3
Switching the laser beams on
▶ Set the selector switch to the
▶ The laser beams are switched on and the laser levels automatically.
The product switches off automatically after one hour.
5.4
Deactivating the automatic power-off feature
▶ Switch the product on and off, then on again within 3 seconds. Laser beam flashes five times to confirm
deactivation.
The product is switched off when the selector switch is set to the OFF position or when battery
power is exhausted.
5.5
Setting the laser beam for the "Inclined line" function
▶ Set the selector switch to the
▶ The laser beams are switched on.
When the "Inclined line" function is active, the pendulum is locked and the laser is not leveled.
The laser beams flash every 5 seconds.
*2341493*
2
position (ON / unlocked).
position (ON / locked).
2341493
66 mm x 116 mm x 145 mm
(2.6 in x 4.6 in x 5.7 in)
590 g
(20.8 oz)
English