Storz IMAGE1 S 4U Rubina Manual De Instrucciones página 43

Ocultar thumbs Ver también para IMAGE1 S 4U Rubina:
41
Hinweise zur
elektromagnetischen
Verträglichkeit (EMV)
Table 3 – Test levels for Radiated and conducted Immunity Tests
Guidance and manufacturer's declaration – electromagnetic immunity
The IMAGE1 S™ 4U Rubina, OPAL1
NIR/ICG camera head is intended for use in the electromagnetic environment specified below. The user of the
®
IMAGE1 S™ 4U Rubina, OPAL1
NIR/ICG camera head should make sure that it is used in such an environment.
®
Immunity tests
EN/IEC 60601 test level
Conducted RF
3 V
rms
disturbances
150 kHz to 80 MHz
acc. to IEC 61000­4­6
Radiated RF
3 V/m
disturbances acc. to
80 MHz to 2.5 GHz
IEC 61000­4­3
Note: At 80 MHz and 800 MHz, the higher frequency range applies.
Note: These guidelines may not apply in all situations. The propagation of electromagnetic quantities is affected by absorptions and reflections of buildings,
objects, and persons.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM
radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters,
an electromagnetic site survey should be considered. If the measured field strength in the location in which the 4U Rubina, OPAL1
is used exceeds the applicable RF compliance level above, the 4U Rubina, OPAL1
If abnormal performance is observed, additional measures may be necessary, such as re­orienting or relocating the 4U Rubina, OPAL1
head.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Information on
electromagnetic
compatibility (EMC)
Compliance level
Electromagnetic environment – guidance
Portable and mobile RF communications equipment should be used
no closer to any part of the IMAGE1 S™ 4U Rubina, OPAL1
camera head, including cables, than the recommended separation
distance calculated from the equation applicable to the frequency of
the transmitter.
Recommended separation distance:
f
3 V
rms
where P is the nominal power of the transmitter in watts [W] according
to the information provided by the manufacturer of the transmitter and
d is the recommended separation distance in meters [m].
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey
in each frequency range
f
3 V/m
h
Interference may occur in the vicinity of equipment marked with the
following symbol:
7
NIR/ICG camera head should be observed to verify normal operation.
®
Indicaciones sobre
compatibilidad
electromagnética (CEM)
should be less than the compliance level
a
.
b
80 MHz to 800 MHz
800 MHz to 2.5 GHz
®
NIR/ICG camera head
NIR/ICG camera
®
®
NIR/ICG
loading