TEST RUN MENU
troubleshooting. Consult to authorized service engineers if
abnormality can not be recovered.
Small sound may be heard from the outdoor unit after turning
ON the power source because the electrical expansion valve
is activated to adjust the opening. Therefore there is no
abnormality of the unit.
Sound may be heard from the outdoor unit for seconds after
running or stopping the compressor, starting or finishing
the defrosting, etc. It generates because of the pressure
difference inside the piping from the compressor. Therefore,
there is no abnormality of the unit.
6.2 FUNCTION SELECTION
1 Press and hold " " (menu) and "
simultaneously for at least 3 seconds during the normal
mode (when unit is not operated). The test run menu is
displayed then.
2 Select "Function Selection" from the test run menu and press
"OK".
Test Run Menu
Test Run
Function Selection
Thermistor Selection
Input/Output
Function 5
Sel.
ADJ
3 Select the indoor unit by pressing "
(This screen is NOT displayed when the number of indoor
units connected with the remote control switch is 1. In this
case, go directly to the step 4).
Function Selection
01-01
01-02
01-03
01-04
Sel.
4 Press "
" and select the item.
Function Selection:01-03
Item
b1
b2
b3
b4
b5
Sel.
Adj.
9
PMML0496 rev.1 - 12/2020
/
?
" (return / help)
01
/
03
OK
Entr
Rtrn
" and press "OK".
All
OK
Entr
Rtrn
Setting
00
01
00
/
00
31
00
00
OK
Entr
Rtrn
Refrigerant cycle number
of indoor unit which
abnormality occurs
00-00
13
Alarm Code:
MODEL
:E .00
Unit model
code
Sel.
5 Press "
" and change the setting.
Function Selection:01-03
Item
b1
b2
b3
b4
b5
Sel.
Adj.
6 Press "OK", then the confirmation screen is displayed.
7 Select "Yes" and press "OK". The test run menu is displayed
after the setting is confirmed. If "No" is pressed, the screen
returns to step 4.
Function Selection:01-03
Confirm function selection
setting?
Yes
Sel.
/
?
8 Press "
" (return / help) on the test run menu to return to
the normal mode.
?
N O T E
To set other units, press "
the screen returns to step 3 (If the number of indoor units connected
with the remote control switch is 1, the screen returns to step 4).
Indoor unit number
which abnormality
occurs
Alarm code
number
Total number of
indoor unit in same
refrigerant cycle as
one that abnormality
AlarmRst
occurs
Address
OK
Entr
Setting
00
01
00
/
00
31
00
00
OK
Entr
Rtrn
No
OK
Entr
Rtrn
/ " (return / help) at steps 4 and 5 so that
?