Ingersoll Rand 35A1-EU Instrucciones página 2

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
WARNING
Always wear eye protection
when operating or perform-
ing maintenance on this
pump.
WARNING
Do not use damaged, frayed
or deteriorated air hoses
and fittings.
AIR STRAINER
Periodically, clean the Air Strainer Screen as follows:
1. Shut off the air supply to the pump.
2. Unscrew the Air Strainer Cap and remove the Air
Strainer Screen.
3. Clean the Screen in a suitable cleaning solution.
IMPELLER ADJUSTMENT
For the most efficient operation of the pump, particularly
against high heads, it is necessary that proper Impeller
clearance be maintained.
1. Pumps are assembled at the factory with a sufficient
quantity of Suction Seal Shims to provide 0.010"
clearance between the faces of the Impeller and the
Suction Seal. When, due to wear, this clearance has
increased to 0.032" (1/32"), remove enough Shims to
obtain the original 0.010" clearance.
2. If decreased efficiency is noted, remove the Impeller
and slip some of the Impeller Shims from the Rotor.
Replace the Impeller and tighten the Impeller Nut.
Rotate the Impeller. Repeat this procedure until
enough Impeller Shims have been removed to cause a
slight drag, then add one 0.010" Shim. Adjust the
clearance between the Impeller and the Suction Seal as
explained in the preceding paragraph) whenever
Impeller Shims have been removed.
WARNING LABEL IDENTIFICATION
Always wear hearing
protection when operating
this pump.
90 psig
Operate at 90 psig (6.2 bar/
(6.2bar/620 kPa)
620 kPa) Maximum air pressure.
ADJUSTMENTS
WARNING
WARNING
OILER ADJUSTMENT
The Pump should use about 3 fluid ounces (90 mL) of oil
during each four hours of operation. The Oiler is adjusted
at the factory, but since flow rate varies somewhat with
temperature, readjustment may be necessary. The rate of
flow is regulated by an Oiler Adjusting Screw, located in
the inner face of the Backhead.
To regulate the Oiler:
Remove the Backhead and turn the Oiler Adjusting Screw.
Turning the Screw clockwise decreases the flow; turning
the Screw counterclockwise increases the flow. Under no
circumstance should the Screw be backed out beyond the
face of the Backhead.
2
WARNING
Always turn off the air sup-
ply and disconnect the air
supply hose before install-
ing, removing or adjusting
any accessory on this pump,
or before performing any
maintenance on this pump.
International Warning Label:
Order Part No. ___________
loading

Este manual también es adecuado para:

35a3-eu