TPD1461
IMPORTANT SAFETY INFORMATION ENCLOSED.
READ THIS MANUAL BEFORE OPERATING PUMP.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION
IN THIS MANUAL INTO THE HANDS OF THE OPERATOR.
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
FORSEEN USE
•
Model 35–EU Sump Pump is a "High Head" pump
that is very popular in mining applications.
•
Ingersoll–Rand is not responsible for customer
modification of pumps for applications on which
Ingersoll–Rand was not consulted.
PLACING PUMPS IN SERVICE
•
Always operate, inspect and maintain this pump in
accordance with all regulations (local, state, federal
and country), that may apply to hand held/hand
operated pneumatic pumps.
•
For safety, top performance, and maximum
durability of parts, operate this pump at 90 psig
(6.2 bar/620 kPa) maximum air pressure at the inlet
with 1" (25 mm) inside diameter air supply hose.
•
Always turn off the air supply and disconnect the
air supply hose before installing, removing or
adjusting any accessory on this pump, or before
performing any maintenance on this pump.
•
Do not use damaged, frayed or deteriorated air
hoses and fittings.
The use of other than genuine Ingersoll–Rand replacement parts may result in safety hazards, decreased pump
performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll–Rand Authorized
Servicenter.
Refer All Communications to the Nearest
Ingersoll–Rand Office or Distributor.
Ingersoll–Rand Company 1995
Printed in U.S.A.
INSTRUCTIONS FOR
MODEL 35–EU SUMP PUMPS
03531175
•
Be sure all hoses and fittings are the correct size
and are tightly secured. See Dwg. TPD905–1 for a
typical piping arrangement.
•
Always use clean, dry air at 90 psig maximum air
pressure. Dust, corrosive fumes and/or excessive
moisture can ruin the motor of an air pump.
•
Do not lubricate pumps with flammable or volatile
liquids such as kerosene, diesel or jet fuel.
•
Do not remove any labels. Replace any damaged
label.
•
This pump is not designed for working in explosive
atmospheres.
•
This pump is not insulated against electric shock.
USING THE PUMP
•
Always wear eye protection when operating or
performing maintenance on this pump.
•
Always wear hearing protection when operating
this pump.
•
Use accessories recommended by Ingersoll–Rand.
•
Do not start or operate this pump unless it is
submerged.
Form P5604–EU
Edition 18
GB
February, 1995