Eaton PLLA M2 Información De Instalación Y Mantenimiento página 6

Idiomas disponibles

Idiomas disponibles

1.
WIRING DIAGRAMS - OPTIONAL SURGE MODULE (PLLA models only)
D
L
BLACK
L
N
WHITE
N
G
G
SOURCE
OF
DRIVER
SUPPLY
HOUSING
GROUND
C
BLACK
WHITE
GREEN
-
+
8
7
PLLA M2 w/SURGE THROUGH-FEED WIRING
NOTES:
Figure 16A. UNV1 Model with SRG Option, Through-feed Wiring Diagram
1.
B
D
L
BLACK
L
N
WHITE
N
G
G
SOURCE
OF
A
DRIVER
SUPPLY
HOUSING
GROUND
C
WIRING DIAGRAMS - PLLA UNV1 DRIVER w/SURGE OPTION
BLACK/ORANGE
BLACK/WHITE
8
7
-
+
PLLA M2 w/SURGE THROUGH-FEED WIRING
Figure 17A. UNV34 Model with SRG Option, Through-feed Wiring Diagram
B
MAINTENANCE GENERAL
1.
Perform visual, electrical and mechanical inspections on a regular basis.
The environment and frequency of use should determine this. However,
it is recommended that checks be made at least once a year. We
recommend an Electrical Preventive Maintenance Program as described
in the National Fire Protection Association Bulletin NFPA No. 70B:
Recommended Practice For Electrical Equipment Maintenance (www.
nfpa.org).
A
2.
The lens should be cleaned periodically to ensure continued lighting
performance. To clean, wipe the lens with a clean, damp cloth. If this is
WIRING DIAGRAMS - PLLA UNV34 DRIVER w/SURGE OPTION
not sufficient, use a mild soap or a liquid cleaner such as Collinite NCF or
Duco #7 . Do not use an abrasive, strong alkaline, or acid cleaner. Damage
8
7
may result.
3.
Visually check for undue heating evidenced by discoloration of wires or
other components, damaged parts or leakage evidenced by water or
corrosion in the interior. Replace all worn, damaged or malfunctioning
components, and clean gasket seals before putting the luminaire back into
service.
4.
Electrically check to make sure that all connections are clean and tight.
Mechanically check that all parts are properly assembled.
5.
Check and re-torque all mounting hardware.
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not
guaranteed. In accordance with Eaton's Crouse-Hinds Division's "Terms and Conditions of Sale," and since conditions of use are outside our control, the purchaser should determine
the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.
BLACK
L
SURGE
MODULE
N
WHITE
(PARALLEL)
G
GREEN
LUMINAIRE 1
+
-
WAGO LUMINAIRE
CONNECTOR
CN2
RED
LED +
L
+
LED -
-
BLUE
LED DRIVER
CN2
N
PLLA4 ONLY
VIOLET
DIM +
G
DIM -
GREY
(OPTIONAL 0-10V DIMMING)
6
BLACK
L
SURGE
MODULE
N
WHITE
(PARALLEL)
G
GREEN
LUMINAIRE 1
+
-
WAGO LUMINAIRE
CONNECTOR
CN2
RED
LED +
L
+
LED -
BLUE
LED DRIVER
CN2
N
PLLA4 ONLY
VIOLET
DIM +
DIM -
GREY
6
(OPTIONAL 0-10V DIMMING)
6
Eaton's Crouse-Hinds Division
1201 Wolf Street Syracuse, NY 13208 • U.S.A.
Copyright© 2022
L
L
N
N
G
G
DRIVER
HOUSING
GROUND
LUMINAIRE 2
(UP TO 8 MAX)
SOURCE
OF
SUPPLY
LED PCBA
LED PCBA
+
-
5
4
Figure 16B. UNV1 Model with SRG Option, Standard Wiring Diagram
L
L
N
N
G
G
DRIVER
HOUSING
GROUND
LUMINAIRE 2
(UP TO 8 MAX)
SOURCE
OF
SUPPLY
LED PCBA
LED PCBA
-
+
-
5
4
Figure 17B. UNV34 Model with SRG Option, Standard Wiring Diagram
REPLACEMENT PARTS (USE LISTED FITTINGS COVERED -
LED DRIVERS, MOUNTING OPTIONS, LED LIGHT ENGINE)
Eaton's Crouse-Hinds series linear LED luminaires are designed to provide
years of reliable lighting performance. However, should the need for
replacement parts arise, they are available through your authorized Eaton's
Crouse-Hinds distributor. Assistance may also be obtained through your local
Eaton's Crouse-Hinds representative or the Eaton's Crouse-Hinds Sales Service
Department, 1201 Wolf Street, Syracuse, New York 13208, Phone 866-764-
5454.
5
4
L
BLACK
L
N
WHITE
N
G
G
BLACK
L
N
WHITE
(PARALLEL)
G
GREEN
DRIVER
LUMINAIRE 1
HOUSING
GROUND
L
BLACK
LED DRIVER
N
WHITE
G
GREEN
-
+
3
PLLA M2 w/SURGE STANDARD WIRING
L
BLACK
THROUGH-FEED WIRING
L
N
WHITE
N
G
G
BLACK
L
WHITE
N
G
GREEN
DRIVER
HOUSING
GROUND
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND
TOLERANCES
TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY
UNLESS OTHERWISE SPECIFIED
ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.
REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH
IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS
.X
±
WRITTEN PERMISSION OF EATON. THIS DRAWING IS ON LOAN
.XX
±
AND IS TO BE RETURNED UPON REQUEST.
.XXX
±
L
MATERIAL:
Material
ANGLES
±
BLACK/ORANGE
... THICK
DIM AND TOL IN ACCORDANCE
Finish
WITH ASME Y14.5 2009.
FINISH:
LED DRIVER
N
CODE ...
THIRD ANGLE PROJECTION
THIRD ANGLE PROJECTION
BLACK/WHITE
ASSY2
CAT2
ASSY1
CAT1
NEXT ASSY.
USED ON
APPLICATION
3
-
+
PLLA M2 w/SURGE STANDARD WIRING
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND
TOLERANCES
TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY
UNLESS OTHERWISE SPECIFIED
ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.
REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH
IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS
.X
WRITTEN PERMISSION OF EATON. THIS DRAWING IS ON LOAN
.XX
AND IS TO BE RETURNED UPON REQUEST.
.XXX
MATERIAL:
Material
ANGLES
... THICK
DIM AND TOL IN ACCORDANCE
Finish
WITH ASME Y14.5 2009.
FINISH:
CODE ...
THIRD ANGLE PROJECTION
THIRD ANGLE PROJECTION
ASSY2
CAT2
ASSY1
CAT1
NEXT ASSY.
USED ON
APPLICATION
3
L
N
G
SURGE
MODULE
DRIVER
HOUSING
GROUND
+
LED PCBA
-
WAGO LUMINAIRE
CONNECTOR
CN2
RED
LED +
+
LED PCBA
LED -
-
BLUE
CN2
PLLA4 ONLY
VIOLET
DIM +
DIM -
GREY
(OPTIONAL 0-10V DIMMING)
2
1
L
N
G
SURGE
MODULE
DRIVER
(PARALLEL)
HOUSING
GROUND
+
LED PCBA
UNLESS OTHERWISE SPECIFIED,
WAGO LUMINAIRE
-
ALL PRIMARY DIMENSIONS
in.
mm
CONNECTOR
ARE IN
INCHES.
CN2
.1
±
.3
DIMENSIONS IN [ ] ARE IN
.01
±
.13
MILLIMETERS.
RED
LED +
.005
±
.000
Title Line 1
ORIGINAL DATE
MM/DD/YYYY
TITLE
+
1.5
±
1.5
LED PCBA
LED -
MM/DD/YYYY
REDRAWN DATE
-
Title Line 2
BLUE
Your Name
DRAWN BY
CN2
PLLA4 ONLY
FIRST MADE FOR Catalog Family
CHECKED BY
Your Name
APPROVED BY
Your Name
SIZE
CODE IDENT. NO.
0000000
DIM +
VIOLET
D
Your name
APPROVED BY
DIM -
GREY
SCALE 2:3
WT.
SHEET 10 OF 11
2
1
(OPTIONAL 0-10V DIMMING)
UNLESS OTHERWISE SPECIFIED,
ALL PRIMARY DIMENSIONS
in.
mm
ARE IN
INCHES.
±
.1
±
.3
DIMENSIONS IN [ ] ARE IN
±
.01
±
.13
MILLIMETERS.
±
.005
±
.000
Title Line 1
ORIGINAL DATE
MM/DD/YYYY
TITLE
±
1.5
±
1.5
MM/DD/YYYY
REDRAWN DATE
Title Line 2
Your Name
DRAWN BY
FIRST MADE FOR Catalog Family
CHECKED BY
Your Name
APPROVED BY
Your Name
SIZE
CODE IDENT. NO.
0000000
D
Your name
APPROVED BY
SCALE 2:3
WT.
SHEET 11 OF 11
2
1
IF 1938
Revision 1
New 04/22
D
C
B
D
A
C
REV.
rev
B
A
REV.
rev
loading