D. M2-PM-KIT-*
1.
Make sure the power is disconnected to the conduit system before
installing the luminaire.
2.
Verify that the clamp internal diameter is consistent with the diameter of
the pole prior to installation. Clamps are available in 1.65 (42mm), 2.00
(51mm) and 2.36 (60mm) sizes (see Figure 5).
3.
Pole mount brackets are spaced 20.75" on the bracket centerlines as
shown in Figure 4.
4.
Tighten two (2) of the provided 1/4" hex bolts and split ring lock washers
on each bracket sub-assembly. Torque to 64 in-lbs (7 .2 N-m).
5.
Remove the two (2) 5/16" screws, lock washers and nuts on each clamp
and remove the upper clamp halves.
6.
Luminaire is now ready for mounting. It is strongly suggested to use
two (2) qualified tradespeople to proceed with the final mounting of the
luminaire. This is recommended to avoid any personal injury or damage to
the luminaire.
7 .
Lift luminaire into position such that the pole fits into the lower clamp
halves.
Do not let the luminaire hang or flex on one bracket at a time. Failing to
comply will result in breakage of bracket and possible injury or death.
8.
Install the two (2) upper clamp halves and the 5/16" screws, lock washers
and nuts on each clamp.
9.
Tighten the nuts on the 5/16" screws evenly using a back and forth
sequence. Torque to 120 in.-lbs. (13.6 N-m).
2 Foot
2 Foot
Length
8
(in)
7
(mm)
NOTES:
1.
A
24.0
610
B
See table below for pipe clamp diameters
B
3
4
6
198
7.8
171
6.7
175.3
6
6.90
2
Figure 4. Pole Mount Installation
A
Cat. #
Configuration
PM Kit 2.0 (trade
8
7
M2-PM-KIT-1.25
size 2")
PM Kit 1.5 (trade
M2-PM-KIT-1.5
size 1 - 1/2")
PM Kit 1.25 (trade
M2-PM-KIT-2.0
size 1 - 1/14")
D
C
B
A
Figure 5. Pole Mount Details
IF 1938 • 04/22
!
WARNING
4 Foot
4 Foot
(in)
6
(mm)
5
4
39.0
991
2
5
5
527.1
20.75
1
A
Dimension (inches)
B
A
B
C
D
D
A
6
5
4
4.331
3.543
2.36
1.693
3.740
2.953
2.00
1.535
3.386
2.598
1.65
1.378
A
C
A
Copyright © 2022, Eaton's Crouse-Hinds Division
E. PENDANT MOUNT INSTRUCTIONS
1.
Make sure the power is disconnected from the conduit system before
installing the luminaire.
2.
For Pendant Mount the conduit should be located in line with the 3/4"
NPT entry on the rear of the luminaire driver housing (see Figure 6).
3.
Luminaire is ready for mounting. It is strongly suggested to use two (2)
qualified tradespeople to proceed with the final mounting of the luminaire.
This is recommended to avoid any personal injury or damage to the
luminaire.
4.
Verify sufficient quantity of Eaton's STL thread lubricant is on conduit
entries and that all unused conduit entries on the end caps are closed
with lubricated plugs (see Figure 13).
5.
Engage threaded conduit in rear driver housing NPT entry and fully tighten
in to desired position for operations.
6.
Tighten set screws on driver housing as shown in Figure 8. Torque set
screws to 20 in-lb (2.3 N-m).
7 .
Luminaire now ready to make electrical connections. See section titled
Wiring The LED Luminaire for detail instructions.
Length
8
A
NOTES:
1.
D
112.9
3
2
4.45
C
1
4
3
B
A
A
4
3
D
A
8
D
C
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND
TOLERANCES
UNLESS OTHERWISE SPECIFIED,
TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY
UNLESS OTHERWISE SPECIFIED
ALL PRIMARY DIMENSIONS
ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.
in.
mm
ARE IN
INCHES.
REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH
IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS
.X
.1
.3
C
±
±
DIMENSIONS IN [ ] ARE IN
WRITTEN PERMISSION OF EATON. THIS DRAWING IS ON LOAN
.XX
±
.01
±
.13
MILLIMETERS.
AND IS TO BE RETURNED UPON REQUEST.
.XXX
±
.005
±
.000
MATERIAL:
Material
ORIGINAL DATE
ANGLES
±
1.5
±
1.5
... THICK
REDRAWN DATE
DIM AND TOL IN ACCORDANCE
Finish
WITH ASME Y14.5 2009.
FINISH:
DRAWN BY
CODE ...
THIRD ANGLE PROJECTION
CHECKED BY
ASSY2
CAT2
APPROVED BY
ASSY1
CAT1
APPROVED BY
NEXT ASSY.
USED ON
APPLICATION
3
2
B
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND
TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY
ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.
REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH
IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS
WRITTEN PERMISSION OF EATON. THIS DRAWING IS ON LOAN
AND IS TO BE RETURNED UPON REQUEST.
Material
MATERIAL:
... THICK
Finish
FINISH:
2 Foot
2 Foot
4 Foot
4 Foot
(in)
(mm)
(in)
(mm)
7
6
24.0
610
39.0
991
1
175.3
6.90
D
D
2
C
A
B
C
2
Figure 6. Pendant Mount Detail View
B
7
6
A
Title Line 1
MM/DD/YYYY
TITLE
MM/DD/YYYY
Title Line 2
Your Name
Your Name
FIRST MADE FOR Catalog Family
Your Name
SIZE
CODE IDENT. NO.
0000000
REV.
D
rev
Your name
SCALE 1:2
WT. 15.84 LB
SHEET 4 OF 5
1
Figure 7. Pendant Assembly with Conduit
Figure 8. Pendant Mount Set Screw Detail
TOLERANCES
UNLESS OTHERWISE SPECIFIED,
UNLESS OTHERWISE SPECIFIED
ALL PRIMARY DIMENSIONS
in.
mm
ARE IN
INCHES.
.X
±
.1
±
.3
DIMENSIONS IN [ ] ARE IN
.XX
±
.01
±
.13
MILLIMETERS.
.XXX
±
.005
±
.000
MM/DD/YYYY
ORIGINAL DATE
ANGLES
±
1.5
±
1.5
TITLE
MM/DD/YYYY
REDRAWN DATE
DIM AND TOL IN ACCORDANCE
WITH ASME Y14.5 2009.
Your Name
DRAWN BY
5
4
3
1
1
D
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND
TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY
ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.
REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH
IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS
WRITTEN PERMISSION OF EATON. THIS DRAWING IS ON LOAN
AND IS TO BE RETURNED UPON REQUEST.
MATERIAL:
FINISH:
D
ASSY2
ASSY1
NEXT ASSY.
5
4
3
THREADED CONDUIT
(NOT PROVIDED BY EATON'S
CROUSE-HINDS)
THREADED CONDUIT
(3/4" NPT STANDARD)
(3/4" NPT STANDARD)
C
THREADED CONDUIT
(3/4" NPT STANDARD)
C
B
B
A
Page 3
Title Line 1
Title Line 2
TOLERANCE
UNLESS OTHERWISE SP
in.
.X
±
.1
.XX
±
.01
.XXX
±
.005
Material
ANGLES
±
1.5
... THICK
DIM AND TOL IN ACC
Finish
WITH ASME Y14.
CODE ...
THIRD ANGLE PRO
CAT2
CAT1
USED ON
APPLICATION
loading