44 | SBM V655 | Maintenance

11. Maintenance

11.1

Cleaning and servicing

!
Before cleaning and servicing, switch off SBM V655
and disconnect mains plug.
!
Do not use any solvent-based cleaning agents. Use
alcohol or similar cleaning agents for plastic parts.
The following work is essential to ensure proper opera-
tion and high performance of the SBM V655:
Servicing
Clean moving mechanical parts, treat with spray oil or ke-
rosene and lubricate with engine oil or a suitable grease.
11.2

Spare and wearing parts

The manufacturer cannot accept any liability for
damage arising from the use of non-genuine replace-
ment parts.
Designation
Standard centering flange
Quick-action clamping nut
Centering cone 42 - 64,5 mm
Centering cone 54 - 79,5 mm
Centering cone 74 - 111,5 mm
Weight pliers
Manual vernier caliper
Test clip
Calibration weight
Calibration weight (calibrated)
Voltage sticker
Direction of wheel rotation sticker
Tab. 2:
Spare and wearing parts
|
656 234
2010-11-22
All manuals and user guides at all-guides.com
11.3
i
1. Flange calibration.
2. Vernier caliper and gauge arm calibration.
3. SBM V655 calibration.
4. Perform reference measurement.
11.3.1
1. The menu is called up from the main page with <F5>
2. Enter the password: <F2> <F5> <F3>.
"
x
Order number
602 400
616 200
632 500
652 862
i
605 600
606 500
11.3.2
629 400
602 700
i
654 377
654 376
1. Fit the flange (refer to Section 5).
100 789
i
653 878
2. Start flange calibration in the calibration menu.
3. Close the wheel guard.
"
"

Calibration

As part of service and upkeep (every six months),
on flange replacement or in the event of measure-
ment inaccuracies, it is advisable to calibrate the
SBM V655 in the following sequence:

Call-up of calibration menu

and then <F2>.
The calibration menu is displayed.
Press <F1> to exit from the calibration menu.

Flange unbalance correction

Follow the instructions shown on the monitor.
Do not clamp the wheel, do not use any clamping
tools.
Press <F2> and <OK>.
« Measurement commences.
Flange calibration completed.
Unbalance set to "0".