Faults
Causes
11
1. Measurement sensor for phase recognition defective
2. No motor operation
17
Weight outside setting range (weight required for balan-
cing is more than 250 g)
18
Wheel data not entered
19
Input signal of right measurement sensor
lower than that of left sensor
20
1. Pedal pressed during measurement
2. Irregular rotational speed of motor
3. Wheel speed below minimum value
21
The PCB has detected an excessively high wheel speed
with the wheel guard open (shaft rotating at high speed
although the machine has not been started): Power sup-
ply unit is deactivated
22
Irregular measurement sensor signals
29
ATTENTION: One vernier caliper not in rest position.
30
Gauge arms deactivated.
31
Pedal being pressed. Deactivation takes place.
32
Pedal has been pressed.
33
Incorrect operating system
Sicam srl società unipersonale
All manuals and user guides at all-guides.com
Faults | SBM V655 | 43
Remedy
1. Check connection of light barrier PCB.
2. Make sure the light barrier PCB is protected
against light and provide a cover if necessary.
3. Check and if necessary replace the light barrier
PCB.
4. Check the mains connection.
1. Check whether the wheel is correctly attached to
the flange.
2. Determine the outer weight position (neverthe-
less), attach a 100 g weight and start a different
measurement.
Enter wheel data before performing measurement.
Interchange the connections of the two measure-
ment sensors.
1. Do not press pedal whilst motor is in operation.
2. Make sure the SBM V655 is not subjected to any
impact during measurement.
3. Check mains voltage (probably too low).
1. Switch off the SBM V655 .
2. Lower the wheel guard, switch the SBM V655 on
again without moving the wheel.
3. If the error message persists, contact customer
service.
1. Check that the light barrier PCB is protected
against light and provide a cover if necessary.
2. Check and if necessary replace the light barrier
PCB.
3. Check and if necessary replace the display PCB.
1. Set vernier caliper to rest position.
2. Repeat calibration of electronic vernier caliper .
Perform calibration prior to reactivation.
Use a different PCB.
656 234
en
|
2010-11-22